OBO BETTERMANN V20-C 4-280 V20-C 4-280 5094627 OBO BETTERMANN SurgeController V20 4-pole design, 280V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V20-C 4-280 5094627 OBO BETTERMANN SurgeController V20 4-pole design, 280V,

V20-C 4-280

5094627

OBO BETTERMANN

1 Pcs.

SurgeController V20 4-pole design, 280V, Surge arrester, 4-pole 280 V. Surge arrester, type 2• For surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 40 kA (8/20) per pole• Plug-in arrester with dynamic cut-off unit and visual function display• High-performance varistor technology Application: Equipotential bonding (LPZ 1 to 2) in main and sub-distributors.* Complete = cover and base

Automation > Surge protection device for power supply systems
Surge , arrestor, type 2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

V20-C 4-280 5094627 Obo Bettermann SurgeController V20 4-pole design, 280V serves as a comprehensive multi-pole surge protection device for safeguarding electrical installations from voltage anomalies. Integrated into primary distribution panels, this unit safely diverts high-energy transients to protect downstream equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 80 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 1,6215 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 280V
  • Installation type: DIN rail 35 mm
  • Integrated back-up fuse: no
  • Lightning protection zone LPZ: 1→2
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage AC: 280 V
  • Maximum discharge current (8/20 μs): 40 kA
  • Network form: TN
  • Nominal discharge current (8/20 µs): 20 kA
  • Nominal voltage AC (50/60 Hz): 230 V

More info

▲
Arrester surge current (8/20 µs) [total]80 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate1,6215 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension280V
Installation typeDIN rail 35 mm
Integrated back-up fuseno
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC280 V
Maximum discharge current (8/20 μs)40 kA
Network formTN
Nominal discharge current (8/20 µs)20 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version4
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
Version for4-pole