OBO BETTERMANN V20-C 2+FS-280 V20-C 2+FS-280 5094632 OBO BETTERMANN SurgeController V20 2-pole with remote signalling, 280V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V20-C 2+FS-280 5094632 OBO BETTERMANN SurgeController V20 2-pole with remote signalling, 280V,

V20-C 2+FS-280

5094632

OBO BETTERMANN

1 Pcs.

SurgeController V20 2-pole with remote signalling, 280V, Surge arrester, 2-pole with remote signalling 280 V. Surge arrester, type 2• Complete unit consisting of cover and base, pre-mounted and ready for connection• Suitable for TN network systems• Plug-in upper part; upper part can be separated from base without tools• With remote signalling and potential-free NO contact for function monitoring• Incl. thermal and dynamic cut-off unit• With visual display of defects• High current conductivity and long service life• Labelled connectionsApplication example: Residential buildings, single-family homes and industrial* Complete = cover and base

Automation > Surge protection device for power supply systems
Surge , arrestor, type 2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Equipped with remote signaling contacts, the Obo Bettermann SurgeController V20 2-pole with remote signalling, 280V functions as a modular type 2 surge arrester for electrical distribution panels. It protects sensitive automation infrastructure by safely diverting transient overvoltage pulses away from internal circuits.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 40 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,8753 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 280V
  • Installation type: DIN rail 35 mm
  • Integrated back-up fuse: no
  • Lightning protection zone LPZ: 1→2
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage AC: 280 V
  • Maximum discharge current (8/20 μs): 40 kA
  • Network form: TN
  • Nominal discharge current (8/20 µs): 20 kA
  • Nominal discharge current (8/20 µs) [L-N]: 20 kA

More info

▲
Arrester surge current (8/20 µs) [total]40 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,8753 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension280V
Installation typeDIN rail 35 mm
Integrated back-up fuseno
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC280 V
Maximum discharge current (8/20 μs)40 kA
Network formTN
Nominal discharge current (8/20 µs)20 kA
Nominal discharge current (8/20 µs) [L-N]20 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version2
Protection ratingIP20
Remote signallingyes
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
Version for2-pole + FS

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.