View larger
V20-C 0-320 5099848 OBO BETTERMANN SurgeController V20 plug-in arrester, 320V,
V20-C 0-320
5099848
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for power supply systems
Surge , arrestor, type 2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing plug-in surge suppression capability, the V20-C 0-320 5099848 OBO BETTERMANN SurgeController V20 plug-in arrester, 320V, is utilized for upgrading or replacing protection modules within existing installations. These arresters help maintain electrical infrastructure integrity by intercepting overvoltage transients before they reach sensitive terminal loads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 20 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,1799 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- Dimension: 320V
- Installation type: On basic element
- Integrated back-up fuse: no
- Lightning protection zone LPZ: 1→2
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage AC: 320 V
- Maximum continuous voltage DC: 420 V
- Maximum discharge current (8/20 μs): 40 kA
- Nominal discharge current (8/20 µs): 20 kA
More info
▲| Arrester surge current (8/20 µs) [total] | 20 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1799 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 320V |
| Installation type | On basic element |
| Integrated back-up fuse | no |
| Lightning protection zone LPZ | 1→2 |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage AC | 320 V |
| Maximum continuous voltage DC | 420 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Network form | TN |
| Nominal discharge current (8/20 µs) | 20 kA |
| Nominal discharge current (8/20 µs) [L-N] | 20 kA |
|---|---|
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 1 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| Test class, type 2 | yes |
| Version for | 1-pin cover; 320 V |