OBO BETTERMANN V10-C 0-280 V10-C 0-280 5093402 OBO BETTERMANN SurgeController V10 plug-in arrester, 280V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V10-C 0-280 5093402 OBO BETTERMANN SurgeController V10 plug-in arrester, 280V,

V10-C 0-280

5093402

OBO BETTERMANN

1 Pcs.

SurgeController V10 plug-in arrester, 280V, Plug-in arrester V10 280 V. Surge arrester, type 2+3 to EN 61643-11• Plug-in upper part; upper part can be separated from base without tools• Incl. thermal and dynamic cut-off unit and visual display of defects• High current conductivity and long service life

Automation > Surge protection device for power supply systems
Surge , arrestor, type 2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The V10-C 0-280 5093402 OBO BETTERMANN SurgeController V10 plug-in arrester functions as a compact surge protection device built to defend electrical installations against moderate transient overvoltages. These components are frequently applied in sub-distribution and terminal distribution enclosures to ensure reliable downstream device operation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 10 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,2496 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 280V
  • Installation type: On basic element
  • Lightning protection zone LPZ: 1→3
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage AC: 280 V
  • Maximum discharge current (8/20 μs): 20 kA
  • Nominal discharge current (8/20 µs): 10 kA
  • Nominal voltage AC (50/60 Hz): 230 V
  • Operating temperature, max.: 80 °C
  • Operating temperature, min.: -40 °C

More info

▲
Arrester surge current (8/20 µs) [total]10 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,2496 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension280V
Installation typeOn basic element
Lightning protection zone LPZ1→3
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC280 V
Maximum discharge current (8/20 μs)20 kA
Network formOther
Nominal discharge current (8/20 µs)10 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version1
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2+3
SPD to IEC 61643-1Class II+III
Test class, type 2yes
Version for1-pole