V10-C 0-280 5093402 OBO BETTERMANN SurgeController V10 plug-in arrester, 280V,
V10-C 0-280
5093402
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for power supply systems
Surge , arrestor, type 2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The V10-C 0-280 5093402 OBO BETTERMANN SurgeController V10 plug-in arrester functions as a compact surge protection device built to defend electrical installations against moderate transient overvoltages. These components are frequently applied in sub-distribution and terminal distribution enclosures to ensure reliable downstream device operation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 10 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,2496 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- Dimension: 280V
- Installation type: On basic element
- Lightning protection zone LPZ: 1→3
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage AC: 280 V
- Maximum discharge current (8/20 μs): 20 kA
- Nominal discharge current (8/20 µs): 10 kA
- Nominal voltage AC (50/60 Hz): 230 V
- Operating temperature, max.: 80 °C
- Operating temperature, min.: -40 °C
More info
▲| Arrester surge current (8/20 µs) [total] | 10 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,2496 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 280V |
| Installation type | On basic element |
| Lightning protection zone LPZ | 1→3 |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage AC | 280 V |
| Maximum discharge current (8/20 μs) | 20 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 10 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
|---|---|
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 1 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2+3 |
| SPD to IEC 61643-1 | Class II+III |
| Test class, type 2 | yes |
| Version for | 1-pole |