View larger
V50-B+C 1+NPE 5093653 OBO BETTERMANN CombiController V50 1-pole + NPE, 280V,
V50-B+C 1+NPE
5093653
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for robust electrical installation protection, the V50-B+C 1+NPE 5093653 OBO BETTERMANN CombiController V50 1-pole + NPE, 280V, by Obo Bettermann functions as a combined lightning current and surge arrester. Such components are typically installed at the main distribution board entry point to divert dangerous transient surges safely away from sensitive facility loads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 50 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 1,0431 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- DC network form: no
- Dimension: 280V
- Installation type: DIN rail 35 mm
- Integrated back-up fuse: no
- IT network form: no
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 12,5 kA
- Lightning surge current (10/350): 25 kA
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage (N-PE): 255 V
More info
▲| Arrester surge current (8/20 µs) [total] | 50 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 1,0431 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | no |
| Dimension | 280V |
| Installation type | DIN rail 35 mm |
| Integrated back-up fuse | no |
| IT network form | no |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 12,5 kA |
| Lightning surge current (10/350) | 25 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage (N-PE) | 255 V |
| Maximum continuous voltage AC | 280 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 30 kA |
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Nominal discharge current (8/20 µs) [N-PE] | 50 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
|---|---|
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 1 |
| Pole version | 1+N/PE |
| Protection level [L-N] | ≤1,3 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | yes |
| TN-C network form | no |
| TN-C-S network form | yes |
| TN-S network form | yes |
| TT network form | yes |
| Version for | 1+NPE |