View larger
V25-B+C 1+NPE+FS 5094444 OBO BETTERMANN CombiController V25 1+1 version with FS, 280V,
V25-B+C 1+NPE+FS
5094444
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A combicontroller with signal contact is an advanced surge protection device that not only limits transient overvoltages but also provides remote status monitoring for preventative maintenance in electrical panels. This Obo Bettermann part, designated as V25-B+C 1+NPE+FS, secures electrical installations by reliably diverting high surge currents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 60 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 1,1557 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- Dimension: 280V
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 7 kA
- Lightning surge current (10/350): 14 kA
- Max. mains-side overcurrent protection: 160
- Maximum back-up fuse: 160 A
- Maximum continuous voltage AC: 280 V
- Maximum continuous voltage DC: 200 V
- Maximum discharge current (8/20 µs): 50 kA
- Nominal discharge current (8/20 µs): 30 kA
- Nominal discharge current (8/20 µs) [L-N]: 30 kA
More info
▲| Arrester surge current (8/20 µs) [total] | 60 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 1,1557 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 280V |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 7 kA |
| Lightning surge current (10/350) | 14 kA |
| Max. mains-side overcurrent protection | 160 |
| Maximum back-up fuse | 160 A |
| Maximum continuous voltage AC | 280 V |
| Maximum continuous voltage DC | 200 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 30 kA |
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Nominal discharge current (8/20 µs) [N-PE] | 30 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
|---|---|
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 1 |
| Pole version | 1+N/PE |
| Protection rating | IP20 |
| Remote signalling | yes |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | yes |
| TN-C-S network form | yes |
| TN-S network form | yes |
| TT network form | yes |
| Version for | 1+NPE with FS |