OBO BETTERMANN V25-B+C 1-280 V25-B+C 1-280 5094418 OBO BETTERMANN CombiController V25 single pole version, 280V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V25-B+C 1-280 5094418 OBO BETTERMANN CombiController V25 single pole version, 280V,

V25-B+C 1-280

5094418

OBO BETTERMANN

1 Pcs.

CombiController V25 single pole version, 280V, Combination arrester V25, 1-pole 280 V. Combination arrester, lightning and surge arrester type 1+2• Complete unit consisting of upper part and base, pre-mounted and ready for connection• For TN systems• Plug-in arrester with dynamic cut-off unit• With visual function display• Protection level decoded:705:Value:RAM1; kV • Encapsulated, non-extinguishing zinc oxide varistor arrester for use in standard distributor housings• Labelled connections Application example: Buildings with open-wire power supply or for setting up lightning protection equipotential bonding in residential buildings.* Complete = cover and base

Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The V25-B+C 1-280 5094418 OBO BETTERMANN CombiController V25 single pole version, 280V, is a versatile surge protective device designed to limit transient overvoltages in industrial and commercial power distribution architectures. It effectively diverts sudden electrical surges to ground, preserving the functional integrity of downstream assets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 30 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,4896 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 280V
  • Lightning protection zone LPZ: 0→2
  • Lightning surge current (10/350 μs): 7 kA
  • Lightning surge current (10/350): 7 kA
  • Max. mains-side overcurrent protection: 160
  • Maximum back-up fuse: 160 A
  • Maximum continuous voltage AC: 280 V
  • Maximum continuous voltage DC: 200 V
  • Maximum discharge current (8/20 μs): 50 kA
  • Network form: TN
  • Nominal discharge current (8/20 µs): 30 kA

More info

▲
Arrester surge current (8/20 µs) [total]30 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,4896 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension280V
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)7 kA
Lightning surge current (10/350)7 kA
Max. mains-side overcurrent protection160
Maximum back-up fuse160 A
Maximum continuous voltage AC280 V
Maximum continuous voltage DC200 V
Maximum discharge current (8/20 μs)50 kA
Network formTN
Nominal discharge current (8/20 µs)30 kA
Nominal discharge current (8/20 µs) [L-N]30 kA
Nominal discharge current (8/20 µs) [N-PE]30 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formyes
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number1
Pole version1
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
Test class, type 2yes
TN network formyes
TN-C network formyes
TN-C-S network formyes
TN-S network formyes
TT network formyes
Version for1-pole

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.