OBO BETTERMANN V25-B+C 0-280 V25-B+C 0-280 5097053 OBO BETTERMANN CombiController V25 plug-in arrester, 280V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V25-B+C 0-280 5097053 OBO BETTERMANN CombiController V25 plug-in arrester, 280V,

V25-B+C 0-280

5097053

OBO BETTERMANN

1 Pcs.

CombiController V25 plug-in arrester, 280V, CombiController V25, upper part 280 V. Combination arrester – type 1+2 • Plug-in arrester can be separated from base without tools and current cut-off in base• Including thermal and dynamic cut-off unit and visual fault display • High current conductivity and long service life

Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The V25-B+C 0-280 5097053 OBO BETTERMANN CombiController V25 plug-in arrester, 280V, by Obo Bettermann functions as a reliable plug-in surge protection module for electrical distribution systems. Industrial facilities use these devices to mitigate transient overvoltages and protect downstream electrical equipment from failure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 30 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,1739 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 280V
  • Installation type: On basic element
  • Lightning protection zone LPZ: 0→2
  • Lightning surge current (10/350 μs): 7 kA
  • Lightning surge current (10/350): 7 kA
  • Max. mains-side overcurrent protection: 160
  • Maximum back-up fuse: 160 A
  • Maximum continuous voltage AC: 280 V
  • Maximum continuous voltage DC: 350 V
  • Maximum discharge current (8/20 μs): 50 kA
  • Nominal discharge current (8/20 µs): 30 kA

More info

▲
Arrester surge current (8/20 µs) [total]30 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,1739 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension280V
Installation typeOn basic element
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)7 kA
Lightning surge current (10/350)7 kA
Max. mains-side overcurrent protection160
Maximum back-up fuse160 A
Maximum continuous voltage AC280 V
Maximum continuous voltage DC350 V
Maximum discharge current (8/20 μs)50 kA
Network formOther
Nominal discharge current (8/20 µs)30 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number1
Pole version1
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
Version for1-pin cover; 280 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.