View larger
V25-B+C 0-280 5097053 OBO BETTERMANN CombiController V25 plug-in arrester, 280V,
V25-B+C 0-280
5097053
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The V25-B+C 0-280 5097053 OBO BETTERMANN CombiController V25 plug-in arrester, 280V, by Obo Bettermann functions as a reliable plug-in surge protection module for electrical distribution systems. Industrial facilities use these devices to mitigate transient overvoltages and protect downstream electrical equipment from failure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 30 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,1739 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- Dimension: 280V
- Installation type: On basic element
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 7 kA
- Lightning surge current (10/350): 7 kA
- Max. mains-side overcurrent protection: 160
- Maximum back-up fuse: 160 A
- Maximum continuous voltage AC: 280 V
- Maximum continuous voltage DC: 350 V
- Maximum discharge current (8/20 μs): 50 kA
- Nominal discharge current (8/20 µs): 30 kA
More info
▲| Arrester surge current (8/20 µs) [total] | 30 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1739 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 280V |
| Installation type | On basic element |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 7 kA |
| Lightning surge current (10/350) | 7 kA |
| Max. mains-side overcurrent protection | 160 |
| Maximum back-up fuse | 160 A |
| Maximum continuous voltage AC | 280 V |
| Maximum continuous voltage DC | 350 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 30 kA |
|---|---|
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 1 |
| Pole version | 1 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| Version for | 1-pin cover; 280 V |