PS4-B+C TT+TNS 5089761 OBO BETTERMANN Protection set 4-pole design, 255V,
PS4-B+C TT+TNS
5089761
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The PS4-B+C TT+TNS 5089761 OBO BETTERMANN Protection set 4-pole design, 255V, is an integrated surge protection assembly configured to protect multi-phase TT and TNS electrical networks. These protection sets are commonly placed at building entry points to handle severe lightning currents and safeguard internal circuitry from transient spikes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 100 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 10,8946 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 50 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 10 mm²
- Dimension: 255V
- Follow current quenching capacity (eff) [N-PE]: 25 kA
- Installation type: DIN rail 35 mm
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 50 kA
- Lightning surge current (10/350): 100 kA
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage (L-N): 255 V
- Maximum continuous voltage (N-PE): 255 V
- Maximum continuous voltage AC: 255 V
More info
▲| Arrester surge current (8/20 µs) [total] | 100 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 10,8946 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 50 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 10 mm² |
| Dimension | 255V |
| Follow current quenching capacity (eff) [N-PE] | 25 kA |
| Installation type | DIN rail 35 mm |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 50 kA |
| Lightning surge current (10/350) | 100 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage (L-N) | 255 V |
| Maximum continuous voltage (N-PE) | 255 V |
| Maximum continuous voltage AC | 255 V |
| Maximum discharge current (8/20 μs) | 100 kA |
| Network form | Other |
|---|---|
| Nominal discharge current (8/20 µs) | 50 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 85 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 85 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3+N/PE |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Short-circuit resistance | 25 kA |
| Short-circuit resistance for max. mains-side overcurrent protection | 25 kA |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| Version for | 3-pole with NPE; 255 V |