OBO BETTERMANN MB 50-3+NPE MB 50-3+NPE 5096675 OBO BETTERMANN Multibase MB50 3-pole + NPE, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MB 50-3+NPE 5096675 OBO BETTERMANN Multibase MB50 3-pole + NPE,

MB 50-3+NPE

5096675

OBO BETTERMANN

1 Pcs.

Multibase MB50 3-pole + NPE, CombiController V50 base. Base for V 50-B+C, combination arrester, lightning and surge arrester, type 1+2 • Suitable for V25-B+C, V20-C and V10-C• Pre-mounted and ready for connection• Multifunction terminals for easy connection with series-mounted devices• Upper parts can be rotated through 180 degrees• 3+1 protection circuit for TN-S and TT network systems Application: Lightning protection equipotential bonding in buildings, even those with external lightning protection of class III and IV, and in standard distributor housings.Base

Automation > Basic element for surge protection device
Surge , arrestor, type 1+2 (office housing)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A multibase acts as a heavy-duty mounting socket for high-capacity surge protection modules, providing secure structural support and terminal connections inside main distribution panels. This Obo Bettermann unit, part number MB 50-3+NPE, supports robust three-phase and neutral grounding architectures.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 50 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 1,3266 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • DC network form: no
  • Dimension: 3+NPE
  • Installation type: DIN rail 35 mm
  • Integrated back-up fuse: no
  • IT network form: no
  • Lightning protection zone LPZ: 0→2
  • Lightning surge current (10/350): 50 kA
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage (N-PE): 255 V
  • Maximum continuous voltage AC: 280 V

More info

▲
Arrester surge current (8/20 µs) [total]50 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate1,3266 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formno
Dimension3+NPE
Installation typeDIN rail 35 mm
Integrated back-up fuseno
IT network formno
Lightning protection zone LPZ0→2
Lightning surge current (10/350)50 kA
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage (N-PE)255 V
Maximum continuous voltage AC280 V
Maximum discharge current (8/20 μs)50 kA
Network formOther
Nominal discharge current (8/20 µs) [N-PE]50 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number3
Pole version3+N/PE
Protection level [L-N]≤1,3
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
TN network formyes
TN-C network formyes
TN-C-S network formyes
TN-S network formyes
TT network formyes
Version for3+NPE base

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.