C 25-B+C 0 5095603 OBO BETTERMANN Lightning current conductor choose N against PE,
C 25-B+C 0
5095603
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A lightning current conductor is an essential component in heavy-duty surge protection schemes, designed to handle high-energy impulse currents and protect electrical infrastructure from direct and indirect lightning strikes. Manufactured by Obo Bettermann under part number C 25-B+C 0, this unit integrates smoothly into panel setups to maintain system integrity.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 30 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,35 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- Dimension: 255V
- Follow current quenching capacity (eff) [N-PE]: 0,1 kA
- Installation type: On basic element
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 25 kA
- Max. mains-side overcurrent protection: 160
- Maximum back-up fuse: 160 A
- Maximum continuous voltage AC: 255 V
- Maximum discharge current (8/20 μs): 50 kA
- Nominal discharge current (8/20 µs): 30 kA
- Nominal discharge current (8/20 µs) [N-PE]: 30 kA
More info
▲| Arrester surge current (8/20 µs) [total] | 30 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,35 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 255V |
| Follow current quenching capacity (eff) [N-PE] | 0,1 kA |
| Installation type | On basic element |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 25 kA |
| Max. mains-side overcurrent protection | 160 |
| Maximum back-up fuse | 160 A |
| Maximum continuous voltage AC | 255 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 30 kA |
|---|---|
| Nominal discharge current (8/20 µs) [N-PE] | 30 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | N/PE |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <100 ns |
| Signalling on device | None |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| Version for | 1-pole cover; 255 V |