OBO BETTERMANN C 25-B+C 0 C 25-B+C 0 5095603 OBO BETTERMANN Lightning current conductor choose N against PE, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

C 25-B+C 0 5095603 OBO BETTERMANN Lightning current conductor choose N against PE,

C 25-B+C 0

5095603

OBO BETTERMANN

1 Pcs.

Lightning current conductor choose N against PE, Plug-in arrester, total spark gap between N and PE 255 V. Plug-in total discharge gap for use between neutral lines (N) and protector (PE) Suitable for use in combination with: • CombiController, type V 25-B+C• SurgeController, type V 20-C• SurgeController, type V 10-C* Complete = Plug-in arrester and base

Automation > Combined arrester for power supply systems
Surge , arrestor, type 1+2 (office housing)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A lightning current conductor is an essential component in heavy-duty surge protection schemes, designed to handle high-energy impulse currents and protect electrical infrastructure from direct and indirect lightning strikes. Manufactured by Obo Bettermann under part number C 25-B+C 0, this unit integrates smoothly into panel setups to maintain system integrity.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 30 kA
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,35 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 255V
  • Follow current quenching capacity (eff) [N-PE]: 0,1 kA
  • Installation type: On basic element
  • Lightning protection zone LPZ: 0→2
  • Lightning surge current (10/350 μs): 25 kA
  • Max. mains-side overcurrent protection: 160
  • Maximum back-up fuse: 160 A
  • Maximum continuous voltage AC: 255 V
  • Maximum discharge current (8/20 μs): 50 kA
  • Nominal discharge current (8/20 µs): 30 kA
  • Nominal discharge current (8/20 µs) [N-PE]: 30 kA

More info

▲
Arrester surge current (8/20 µs) [total]30 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,35 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension255V
Follow current quenching capacity (eff) [N-PE]0,1 kA
Installation typeOn basic element
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)25 kA
Max. mains-side overcurrent protection160
Maximum back-up fuse160 A
Maximum continuous voltage AC255 V
Maximum discharge current (8/20 μs)50 kA
Network formOther
Nominal discharge current (8/20 µs)30 kA
Nominal discharge current (8/20 µs) [N-PE]30 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole versionN/PE
Protection ratingIP20
Remote signallingno
Response time<100 ns
Signalling on deviceNone
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
Version for1-pole cover; 255 V

Product Datasheet