OBO BETTERMANN MDP-2 D-12-T-10 5098415 OBO BETTERMANN ARRESTER MDP-2 D-12-T-10 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5098415 OBO BETTERMANN ARRESTER MDP-2 D-12-T-10

MDP-2 D-12-T-10

5098415

OBO BETTERMANN

1 Pcs.

ARRESTER MDP-2 D-12-T-10 Series protection device, 2-pole, 12 V version. Lightning barrier with test function; 12 V version • Rated load current 10 A• Protection device for multi-wire systems• Direct shield earthing and screwless connection terminals• Space-saving width of just 8.7 mm • Protection circuit testable with Life Control• High bandwidth to 100 MHz• UL-listed (4DG1) Application: Universal use on 35 mm DIN profile rail in any standard distribution housing.

Automation > Surge protection device for data networks/MCR-technology
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ApprovalsUL
Capacity (wire-wire)<40 pF
CO2 Footprint (GWP) Cradle-to-Gate0,2794 kg CO2e / 1 Piece
Connection cross-section, flexible, max.2,5 mm²
Connection cross-section, flexible, min.0,14 mm²
Connection cross-section, multi-wire, max.1,5 mm²
Connection cross-section, multi-wire, min.0,14 mm²
Connection cross-section, rigid, max.2,5 mm²
Connection cross-section, rigid, min.0,14 mm²
Cut-off frequency100 MHz
Dimension12V
Earthing via:DIN rail
Impulse durability wire-wireC1: 0,5 kV / 0,25 kA (8/20µs)
Insertion loss≤3 dB
Insulation resistance>100 MΩ
KategorieType 1+2+3 / D1+C2+C1
Lightning protection zone LPZ0→3
Maximum continuous voltage AC10,5 V
Maximum continuous voltage DC15 V
Nominal load current AC0,7 A
Nominal load current DC10 A
Nominal voltage12 V
Number of poles2
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Plug-in systemTerminal
Protection level wire-earth<800 V
Protection level wire-wire<55 V
Protection ratingIP20
ScreeningDirect
Shielding connection availableyes
Signalling on deviceReadable
SPD to IEC 61643-21Class I+II+III / D1+C2+C1
Testing standardIEC 61643-21
Total discharge current (10/350)D1: 1 kA
Total discharge current (8/20)5 kA