View larger
5095370 OBO BETTERMANN DOWNLOADER T. 2 V20-0-440
V20-0-440
5095370
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Acting as a type 2 surge arrester, the 5095370 OBO BETTERMANN DOWNLOADER T. 2 V20-0-440 is deployed in electrical switchgear to protect downstream industrial machinery from the damaging effects of transient voltage spikes. This modular protective element integrates smoothly into established safety setups to divert surge energy safely away from critical assets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Approvals: UL
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,1499 kg CO2e / 1 Piece
- Dimension: 440V
- Housing material surge protection components: PA UL 94 V-0
- Installation type: On basic element
- Integrated back-up fuse: no
- Maximum continuous voltage (L-N): 440 V
- Maximum continuous voltage AC: 440 V
- Maximum discharge current (8/20 μs): 40 kA
- Maximum discharge current (8/20 μs) [L-N]: 40 kA
- Minimum distance: 1,5 mm
- Nominal discharge current (8/20 µs): 20 kA
- Nominal discharge current (8/20 µs) [L-N]: 20 kA
- Nominal voltage AC (50/60 Hz): 400 V
- Operating temperature, max.: 80 °C
More info
▲| Approvals | UL |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1499 kg CO2e / 1 Piece |
| Dimension | 440V |
| Housing material surge protection components | PA UL 94 V-0 |
| Installation type | On basic element |
| Integrated back-up fuse | no |
| Maximum continuous voltage (L-N) | 440 V |
| Maximum continuous voltage AC | 440 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Maximum discharge current (8/20 μs) [L-N] | 40 kA |
| Minimum distance | 1,5 mm |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 20 kA |
| Nominal discharge current (8/20 µs) [L-N] | 20 kA |
| Nominal voltage AC (50/60 Hz) | 400 V |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 1 |
| Pole version | 1 |
| Protection level [L-N] | ≤2 |
| Protection rating | IP20 |
| Remote signalling | no |
| Short-circuit resistance for max. mains-side overcurrent protection | 50 kA eff |
| Short-circuit resistant | yes |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| SPD to UL 1449 | Type 4 |
| Test class, type 2 | yes |