OBO BETTERMANN V20-0-150 5095362 OBO BETTERMANN DOWNLOADER T. 2 V20-0-150 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5095362 OBO BETTERMANN DOWNLOADER T. 2 V20-0-150

V20-0-150

5095362

OBO BETTERMANN

1 Pcs.

DOWNLOADER T. 2 V20-0-150 Plug-in arrester V20 150 V. Surge arrester, type 2 • For surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44) • Discharge capacity to 40 kA (8/20) per pole through high-performance varistors • Modular, plug-in arrester with dynamic cut-off unit and visual status display • Locking mechanism with vibration protection and voltage keying • Plastic (UL 94 V-0)

Automation > Surge protection device for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The 5095362 OBO BETTERMANN DOWNLOADER T. 2 V20-0-150 is a type 2 surge arrester configured to protect electrical systems against transient overvoltages resulting from switching operations or indirect lightning strikes. Equipment in this category is standardly used in commercial and industrial electrical distribution cabinets to maintain operational continuity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Approvals: VDE, KEMA, UL, ÖVE
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,1553 kg CO2e / 1 Piece
  • Dimension: 150V
  • Housing material surge protection components: PA UL 94 V-0
  • Installation type: On basic element
  • Integrated back-up fuse: no
  • Maximum continuous voltage (L-N): 150 V
  • Maximum continuous voltage AC: 150 V
  • Maximum discharge current (8/20 μs): 40 kA
  • Maximum discharge current (8/20 μs) [L-N]: 40 kA
  • Minimum distance: 1,5 mm
  • Nominal discharge current (8/20 µs): 20 kA
  • Nominal discharge current (8/20 µs) [L-N]: 20 kA
  • Nominal voltage AC (50/60 Hz): 120 V
  • Operating temperature, max.: 80 °C

More info

▲
ApprovalsVDE, KEMA, UL, ÖVE
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,1553 kg CO2e / 1 Piece
Dimension150V
Housing material surge protection componentsPA UL 94 V-0
Installation typeOn basic element
Integrated back-up fuseno
Maximum continuous voltage (L-N)150 V
Maximum continuous voltage AC150 V
Maximum discharge current (8/20 μs)40 kA
Maximum discharge current (8/20 μs) [L-N]40 kA
Minimum distance1,5 mm
Network formOther
Nominal discharge current (8/20 µs)20 kA
Nominal discharge current (8/20 µs) [L-N]20 kA
Nominal voltage AC (50/60 Hz)120 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number1
Pole version1
Protection level [L-N]≤0,8
Protection ratingIP20
Remote signallingno
Residual voltage [L-N] @ 1 kA0,5 kV
Residual voltage [L-N] @ 5 kA0,6 kV
Short-circuit resistance for max. mains-side overcurrent protection50 kA eff
Short-circuit resistantyes
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
SPD to UL 1449Type 4
Test class, type 2yes