OBO BETTERMANN V50-0-320 5093509 OBO BETTERMANN ARRESTER 1+2 V50-0-320 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5093509 OBO BETTERMANN ARRESTER 1+2 V50-0-320

V50-0-320

5093509

OBO BETTERMANN

1 Pcs.

ARRESTER 1+2 V50-0-320 Plug-in arrester V50 320 V. Combination arrester, type 1+2 • For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305) • Lightning current discharge capacity of 12.5 kA (10/350) per pole • Modular, plug-in arrester with dynamic cut-off unit and visual status display • Locking mechanism with vibration protection and voltage keying • Plastic (UL 94 V-0)

Automation > Combined arrester for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Providing reliable transient voltage limitation, the Obo Bettermann 5093509 OBO BETTERMANN ARRESTER 1+2 V50-0-320 is an essential protective component for electrical installations. It is typically integrated into distribution panels to suppress voltage spikes and protect connected downstream machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Approvals: VDE, KEMA, UL, ÖVE
  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,2308 kg CO2e / 1 Piece
  • Conductor cross-section, flexible (fine-wire), max.: 2 AWG
  • Conductor cross-section, flexible (fine-wire), max.: 35 mm²
  • Conductor cross-section, flexible (fine-wire), min.: 1,5 mm²
  • Conductor cross-section, flexible (fine-wire), min.: 16 AWG
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 2 AWG
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 16 AWG
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 1,5 mm²
  • Connection cross-section, FM terminals, max.: 1,5 mm²
  • Connection cross-section, FM terminals, max.: 16 AWG
  • Connection cross-section, FM terminals, min.: 0,5 mm²
  • Connection cross-section, FM terminals, min.: 21 AWG
  • Dimension: 320V

More info

▲
ApprovalsVDE, KEMA, UL, ÖVE
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,2308 kg CO2e / 1 Piece
Conductor cross-section, flexible (fine-wire), max.2 AWG
Conductor cross-section, flexible (fine-wire), max.35 mm²
Conductor cross-section, flexible (fine-wire), min.1,5 mm²
Conductor cross-section, flexible (fine-wire), min.16 AWG
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), max.2 AWG
Conductor cross-section, rigid (single-wire/multiwire), min.16 AWG
Conductor cross-section, rigid (single-wire/multiwire), min.1,5 mm²
Connection cross-section, FM terminals, max.1,5 mm²
Connection cross-section, FM terminals, max.16 AWG
Connection cross-section, FM terminals, min.0,5 mm²
Connection cross-section, FM terminals, min.21 AWG
Dimension320V
Housing material surge protection componentsPA UL 94 V-0
Installation typeDIN rail 35 mm
Integrated back-up fuseno
Lightning surge current (10/350 μs)12,5 kA
Max. mains-side overcurrent protection160 A gL/gG
Maximum back-up fuse160 A
Maximum continuous voltage (L-N)320 V
Maximum continuous voltage AC320 V
Maximum discharge current (8/20 μs)50 kA
Maximum discharge current (8/20 μs) [L-N]50 kA
Minimum distance1,5 mm
Network formAll
Nominal discharge current (8/20 µs)30 kA
Nominal discharge current (8/20 µs) [L-N]30 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number1
Pole version1
Protection level [L-N]≤1,4
Protection ratingIP20
Remote signallingno
Residual voltage [L-N] @ 1 kA0,9 kV
Residual voltage [L-N] @ 12.5 kA1,1 kV
Residual voltage [L-N] @ 5 kA1 kV
Response time<25 ns
Short-circuit resistance for max. mains-side overcurrent protection50 kA eff
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
SPD to UL 1449Type 4
Torque4 Nm
TOV voltage [L-N] ‒ fail safe mode ‒ 120 min.440 V
TOV voltage [L-N] ‒ withstand mode ‒ 5 s335 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.