OBO BETTERMANN USM-LED 230-65 5092478 OBO BETTERMANN PROTECTION FINE ÜSM-LED 230-65 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5092478 OBO BETTERMANN PROTECTION FINE ÜSM-LED 230-65

USM-LED 230-65

5092478

OBO BETTERMANN

25 Pcs.

PROTECTION FINE ÜSM-LED 230-65 Surge protection for LED systems 230 V IP65. Surge protection module type 2+3 to DIN EN 61643-11 for 230/400 V power grids.Appropriate for the protection of LED lighting and the LED driver. • With visual function display• Small size for the installation in the mast connection box• IP65 and with 25 cm connection cable• 1+NPE protective circuit with a maximum discharge capacity of 20 kA• Surge limitation under 1,300 V or 1,000 V @ 5 kA• Available with or without cut-off function of the lamp in case of malfunctionApplication: Universally deployable in all lighting systemsTo protect electronic devices such as LED luminaires against surge voltages

Automation > Surge protection device for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

As a specialized fine protection device, the 5092478 OBO BETTERMANN PROTECTION FINE ÜSM-LED 230-65 is deployed in industrial and commercial electrical networks to safeguard sensitive terminal equipment against residual overvoltages. These compact devices are typically installed directly upstream of loads to provide an additional layer of protection beyond main distribution panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrester surge current (8/20 µs) [total]: 20 kA
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,0131 kg CO2e / 1 Piece
  • Connecting cable length: 0,25 m
  • Dimension: 230V
  • Installation type: Miscellaneous
  • Integrated back-up fuse: no
  • Lightning protection zone LPZ: 2→3
  • Max. mains-side overcurrent protection: 16
  • Maximum back-up fuse: 16 A
  • Maximum continuous voltage (L-N): 255 V
  • Maximum continuous voltage (N-PE): 255 V
  • Maximum continuous voltage AC: 255 V
  • Maximum discharge current (8/20 μs): 20 kA
  • Maximum discharge current (8/20 μs) [L-N]: 20 kA
  • Maximum discharge current (8/20 μs) [N-PE]: 20 kA
  • Nominal discharge current (8/20 µs): 10 kA

More info

▲
Arrester surge current (8/20 µs) [total]20 kA
CO2 Footprint (GWP) Cradle-to-Gate0,0131 kg CO2e / 1 Piece
Connecting cable length0,25 m
Dimension230V
Installation typeMiscellaneous
Integrated back-up fuseno
Lightning protection zone LPZ2→3
Max. mains-side overcurrent protection16
Maximum back-up fuse16 A
Maximum continuous voltage (L-N)255 V
Maximum continuous voltage (N-PE)255 V
Maximum continuous voltage AC255 V
Maximum discharge current (8/20 μs)20 kA
Maximum discharge current (8/20 μs) [L-N]20 kA
Maximum discharge current (8/20 μs) [N-PE]20 kA
Network formOther
Nominal discharge current (8/20 µs)10 kA
Nominal discharge current (8/20 µs) [L-N]10 kA
Nominal discharge current (8/20 µs) [N-PE]10 kA
Nominal voltage AC (50/60 Hz)230 V
OBO_Nominal load current (input/output terminal)16 A
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version1+N/PE
Protection level [L-N]≤1,3
Protection ratingIP65
Remote signallingno
Response time<25 ns
Short-circuit resistantno
Signalling on deviceVisual
SPD to EN 61643-11Type 2+3
SPD to IEC 61643-1Class II+III
Test class, type 2yes
Test class, type 3yes
Version for1+NPE

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.