As a specialized fine protection device, the 5092478 OBO BETTERMANN PROTECTION FINE ÜSM-LED 230-65 is deployed in industrial and commercial electrical networks to safeguard sensitive terminal equipment against residual overvoltages. These compact devices are typically installed directly upstream of loads to provide an additional layer of protection beyond main distribution panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 20 kA
- CO2 Footprint (GWP) Cradle-to-Gate: 0,0131 kg CO2e / 1 Piece
- Connecting cable length: 0,25 m
- Dimension: 230V
- Installation type: Miscellaneous
- Integrated back-up fuse: no
- Lightning protection zone LPZ: 2→3
- Max. mains-side overcurrent protection: 16
- Maximum back-up fuse: 16 A
- Maximum continuous voltage (L-N): 255 V
- Maximum continuous voltage (N-PE): 255 V
- Maximum continuous voltage AC: 255 V
- Maximum discharge current (8/20 μs): 20 kA
- Maximum discharge current (8/20 μs) [L-N]: 20 kA
- Maximum discharge current (8/20 μs) [N-PE]: 20 kA
- Nominal discharge current (8/20 µs): 10 kA
More info
▲| Arrester surge current (8/20 µs) [total] | 20 kA |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 0,0131 kg CO2e / 1 Piece |
| Connecting cable length | 0,25 m |
| Dimension | 230V |
| Installation type | Miscellaneous |
| Integrated back-up fuse | no |
| Lightning protection zone LPZ | 2→3 |
| Max. mains-side overcurrent protection | 16 |
| Maximum back-up fuse | 16 A |
| Maximum continuous voltage (L-N) | 255 V |
| Maximum continuous voltage (N-PE) | 255 V |
| Maximum continuous voltage AC | 255 V |
| Maximum discharge current (8/20 μs) | 20 kA |
| Maximum discharge current (8/20 μs) [L-N] | 20 kA |
| Maximum discharge current (8/20 μs) [N-PE] | 20 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 10 kA |
| Nominal discharge current (8/20 µs) [L-N] | 10 kA |
| Nominal discharge current (8/20 µs) [N-PE] | 10 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
|---|---|
| OBO_Nominal load current (input/output terminal) | 16 A |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 1+N/PE |
| Protection level [L-N] | ≤1,3 |
| Protection rating | IP65 |
| Remote signalling | no |
| Response time | <25 ns |
| Short-circuit resistant | no |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2+3 |
| SPD to IEC 61643-1 | Class II+III |
| Test class, type 2 | yes |
| Test class, type 3 | yes |
| Version for | 1+NPE |