OBO BETTERMANN USM-ST-230-1P+PE ÜSM-ST-230-1P+PE 5092441 OBO BETTERMANN PROTECTION FINE ÜSM-ST-230-1P+PE View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ÜSM-ST-230-1P+PE 5092441 OBO BETTERMANN PROTECTION FINE ÜSM-ST-230-1P+PE

USM-ST-230-1P+PE

5092441

OBO BETTERMANN

1 Pcs.

PROTECTION FINE ÜSM-ST-230-1P+PE ÜSM-ST-230-1P+PE protection device, for 230V power outlets, Fine power protection 230 V protective contact sockets. Surge protection / fine power protection, type 3, to EN 61643-11 for protective contact sockets.• Thermal cut-off unit with acoustic defect signalling• Y protection circuit for increased safety• Mounting through snapping onto the support ring of the socket• Halogen-free plastic (UL 94 V-0)• Labelling of the socket with supplied signApplication: For retrofitting on standard Schuko sockets.

Automation > Surge protection device for terminal equipment
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Obo Bettermann produces the ÜSM-ST-230-1P+PE fine protection unit for wall socket installations, shielding sensitive electronic consumers against high-voltage surges. These specialized socket adapters help prevent costly hardware failures caused by secondary lightning effects and switching impulses.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Nominal voltage AC (EF004220): 230 V
  • Max. continuous voltage AC (EF004198): 255 V
  • Voltage protection level (EF003525): 1.5 kV
  • Voltage protection level L-N (EF004236): 1500 kV
  • Number of poles (EF001391): 2
  • Mounting method (EF000003): Wall socket
  • Signalling at the device (EF004241): Acoustic
  • Category type 3 (EF004231): Yes
  • Degree of protection (IP) (EF005474): IP20

More info

▲
Arrester surge current (8/20 µs) [total]5 kA
CO2 Footprint (GWP) Cradle-to-Gate0,0333 kg CO2e / 1 Piece
Combined voltage protection level [L-PE]1500 kV
Connecting cable length0,1 m
Dimension230V
Installation typeWall socket
Lightning protection zone LPZ2→3
Max. mains-side overcurrent protection16
Maximum back-up fuse16 A
Maximum continuous voltage AC255 V
Maximum discharge current (8/20 μs)5 kA
Network formOther
Nominal discharge current (8/20 µs)3 kA
Nominal voltage AC (50/60 Hz)230 V
OBO_Nominal load current (input/output terminal)16 A
Operating temperature, max.40 °C
Operating temperature, min.-5 °C
Permitted temperature range, max.40 °C
Permitted temperature range, min.-5 °C
Pole number2
Protection level wire-earth1500 V
Protection level [L-N]≤1500
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceAcoustic
SPD to EN 61643-11Type 3
SPD to IEC 61643-1Class III
Test class, type 3yes
Version forAcoustic function display

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.