View larger
5088651 OBO BETTERMANN BOX PROTEC. VG-C DCPH1000-4S
VG-C DCPH1000-4S
5088651
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for photovoltaic installations, the 5088651 OBO BETTERMANN BOX PROTEC. VG-C DCPH1000-4S houses essential protective equipment to safeguard DC solar arrays from overvoltage transients. Generator junction boxes and protective enclosures are deployed in renewable energy setups to aggregate string outputs and protect solar inverters from lightning strikes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Anschlussart Generatoranschlusskasten: Tension spring terminal
- CO2 Footprint (GWP) Cradle-to-Gate: 2,3932 kg CO2e / 1 Piece
- Colour: Light grey
- RAL 7035: None
- Conductor cross-section, rigid (single-wire/multiwire), max.: 6 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 0,5 mm²
- DC network form: yes
- Depth: 122 mm
- Dimension: 1000V DC
- Entries per MPPT: 4
- Entry fuse: 10 A
- Equipped with load-break switch: no
- Exits per MPPT: 4
- For fuse size: 10x38 mm
- Fuse type: gPV (full-range photovoltaic protection) [Bitte prüfen, ob so in Ordnung]
- Installation type: Pre-mounted in the housing
- IT network form: no
More info
▲| Anschlussart Generatoranschlusskasten | Tension spring terminal |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 2,3932 kg CO2e / 1 Piece |
| Colour | Light grey; RAL 7035 |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 6 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 0,5 mm² |
| DC network form | yes |
| Depth | 122 mm |
| Dimension | 1000V DC |
| Entries per MPPT | 4 |
| Entry fuse | 10 A |
| Equipped with load-break switch | no |
| Exits per MPPT | 4 |
| For fuse size | 10x38 mm |
| Fuse type | gPV (full-range photovoltaic protection) [Bitte prüfen, ob so in Ordnung] |
| Installation type | Pre-mounted in the housing |
| IT network form | no |
| Lightning protection zone LPZ | 1→2 |
| Max. Input current per string | 30 A |
| Max. Input voltage DC | 1000 V |
| Max. Output current | 30 A |
| Maximum continuous voltage DC | 1000 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Monitoring function | no |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 20 kA |
|---|---|
| Number of cable entries | 16 |
| Number of inputs | 4 |
| Number of MPPTs | 1 |
| Number of string inputs | 4 |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Protection rating | IP65 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| String fuse | 1-pole |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Type of entry | Gland |
| Version for | Type 2 in housing with 4 PV fuses (10 A) |