OBO BETTERMANN VG-C DCPH1000-4S 5088651 OBO BETTERMANN BOX PROTEC. VG-C DCPH1000-4S View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5088651 OBO BETTERMANN BOX PROTEC. VG-C DCPH1000-4S

VG-C DCPH1000-4S

5088651

OBO BETTERMANN

1 Pcs.

BOX PROTEC. VG-C DCPH1000-4S Generator connection box, type 2, with four 10 A fuses for 4 x 1 string. System solution for photovoltaic fuses for photovoltaic inverters with 1 MPP tracker• Error-resistant Y circuit to VDE 0100-712 (50539-12) • Low DC protection level: < 4.0 kV (Voc max = 1,000 V DC with V20-C/0-500PV) • (+) poles protected via 4 photovoltaic fuses 10x38 mm 10 A, 1,000 V DC protected• 4 (-) poles via terminals up to 6 mm² switched in parallel in the housing, up to 30 A DC per terminal• Pre-mounted in polycarbonate housing (IP65), UV- and weather-resistant for use in protected outside area, including cable gland kitFor DC protection of the inverter in photovoltaic systems.If there is a danger of condensation forming through wind, ice, temperature or sunlight, further measures may be necessary!

Automation > Surge protection device for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Anschlussart GeneratoranschlusskastenTension spring terminal
CO2 Footprint (GWP) Cradle-to-Gate2,3932 kg CO2e / 1 Piece
ColourLight grey; RAL 7035
Conductor cross-section, rigid (single-wire/multiwire), max.6 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.0,5 mm²
DC network formyes
Depth122 mm
Dimension1000V DC
Entries per MPPT4
Entry fuse10 A
Equipped with load-break switchno
Exits per MPPT4
For fuse size10x38 mm
Fuse typegPV (full-range photovoltaic protection) [Bitte prüfen, ob so in Ordnung]
Installation typePre-mounted in the housing
IT network formno
Lightning protection zone LPZ1→2
Max. Input current per string30 A
Max. Input voltage DC1000 V
Max. Output current30 A
Maximum continuous voltage DC1000 V
Maximum discharge current (8/20 μs)40 kA
Monitoring functionno
Network formDC
Nominal discharge current (8/20 µs)20 kA
Number of cable entries16
Number of inputs4
Number of MPPTs1
Number of string inputs4
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Protection ratingIP65
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
String fuse1-pole
TN network formno
TN-C network formno
TN-C-S network formno
TN-S network formno
TT network formno
Type of entryGland
Version forType 2 in housing with 4 PV fuses (10 A)