OBO BETTERMANN LSA-BF-180 5084024 OBO BETTERMANN COMBINED PROTECTION P/LSA PLUS View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5084024 OBO BETTERMANN COMBINED PROTECTION P/LSA PLUS

LSA-BF-180

5084024

OBO BETTERMANN

1 Pcs.

COMBINED PROTECTION P/LSA PLUS Combination protection device LSA BF 180. LSA basic and fine protection, for application in MCR systems • Basic and fine protection• Coarse protection using fail-safe technology• With PTC protection components against overcurrent• Max. voltage: 180 VApplication: Directly on LSA-Plus separating strip or connection rails with earthing rail (e.g. OBO LSA-A-LEI (5084 00 8) or OBO LSA-T-LEI (5084 01 2), and OBO LSA-E (5084 03 2))Combination protection device for a two-core

Automation > Combined arrester for data networks/MCR-technology
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Designed for telecommunications and signal transmission infrastructures, the 5084024 OBO BETTERMANN COMBINED PROTECTION P/LSA PLUS provides robust defense against transient overvoltages. This type of protective module is commonly inserted into LSA distribution blocks to protect sensitive network cards and communication equipment from lightning-induced surges. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Capacity (wire-earth): < 50 pF
  • Capacity (wire-wire): < 50 pF
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,0152 kg CO2e / 1 Piece
  • Dimension: 180V
  • Impulse durability wire-earth: C2: 5 kV / 2,5 kA (8/20µs)
  • Impulse durability wire-wire: C2: 5 kV / 2,5 kA (8/20µs)
  • Insulation resistance: > 1 GΩ
  • Kategorie: Type 1+2+3 / D1+C2+C1
  • Lightning protection zone LPZ: 0→3
  • Maximum continuous voltage AC: 120 V
  • Maximum continuous voltage DC: 180 V
  • Nominal load current AC: 0,08 A
  • Nominal load current DC: 0,12 A
  • Number of poles: 2
  • Permitted temperature range, max.: 80 °C
  • Permitted temperature range, min.: -40 °C

More info

▲
Capacity (wire-earth)< 50 pF
Capacity (wire-wire)< 50 pF
CO2 Footprint (GWP) Cradle-to-Gate0,0152 kg CO2e / 1 Piece
Dimension180V
Impulse durability wire-earthC2: 5 kV / 2,5 kA (8/20µs)
Impulse durability wire-wireC2: 5 kV / 2,5 kA (8/20µs)
Insulation resistance> 1 GΩ
KategorieType 1+2+3 / D1+C2+C1
Lightning protection zone LPZ0→3
Maximum continuous voltage AC120 V
Maximum continuous voltage DC180 V
Nominal load current AC0,08 A
Nominal load current DC0,12 A
Number of poles2
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Plug-in systemOther
Protection level wire-earth<300 V
Protection level wire-wire<300 V
Protection ratingIP20
Series resistance per wire10 Ω ± 10 %
SPD to IEC 61643-21Class I+II+III / D1+C2+C1
Testing standardIEC 61643-21
Total discharge current (10/350)0,5 kA
Total discharge current (8/20)5 kA
Version forBasic and fine protection

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.