MURRELEKTRONIK 9000-41190-0000001 9000-41190-0000001 MURRELEKTRONIK Mico Pro Power module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

9000-41190-0000001 MURRELEKTRONIK Mico Pro Power module

9000-41190-0000001

9000-41190-0000001

MURRELEKTRONIK

1 unit


Automation > MICO, current distribution
MICO, current distribution

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Murrelektronik 9000-41190-0000001 Mico Pro Power module supplies and monitors primary power distribution for modular current monitoring systems in automated machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Operating voltage: 12 V DC; 24 V DC (9...30 V DC)
  • Total current: max. 40 A
  • Input voltage (ON): 9...30 V DC
  • Impulse length (ON): "high" 120 ms
  • Input voltage (CTRL): 9...30 V DC
  • Impulse length (CTRL): OFF "high" 40/400 ms, ON "high" 20/200 ms
  • Early warning (90%): max. 30 V AC/DC
  • Group alarm output: max. 30 V AC/DC
  • Connection: Bridge system
  • Connection: Push-In spring clamp terminals
  • Cross section (rigid): 0.75...16 mm² (AWG 20...4)
  • Cross section (flex): 0.75...16 mm² (AWG 20...4)
  • Protection: IP20
  • Bridging concept: Bridge set (max. 40 A)
  • Mounting method: 61961DIN-rail mountable TH35 (EN 60715)
  • Shock load: 1/2 sin 30 g, 11 ms

More info

▲
Mico Pro® PM 24 V DC/40 A
Cover plate included (heavy duty)
Shock load
1/2 sin 30 g, 11 ms
Build your own Mico Pro® online:
https://micopro.murrelektronik.com
Input
Operating voltage12 V DC; 24 V DC (9...30 V DC)
Total currentmax. 40 A
Control inputs
Input voltage (ON)9...30 V DC
Impulse length (ON)"high" 120 ms
Input voltage (CTRL)9...30 V DC
Impulse length (CTRL)OFF "high" 40/400 ms, ON "high" 20/200 ms
Control outputs
Early warning (90%)max. 30 V AC/DC
Group alarm outputmax. 30 V AC/DC
Connections (IN)
ConnectionBridge system
Connections (OUT)
ConnectionPush-In spring clamp terminals
Cross section (rigid)0.75...16 mm² (AWG 20...4)
Cross section (flex)0.75...16 mm² (AWG 20...4)
General data
ProtectionIP20
Bridging conceptBridge set (max. 40 A)
Mounting method61961DIN-rail mountable TH35 (EN 60715)
Shock load1/2 sin 30 g, 11 ms
Temperature range-25...+55 °C (storage temperature -40...+80 °C)
Dimensions H×W×D130×24×114 mm
Output
Parallel usage/serial usage-/Selectivity in 2 levels
Commercial data
country of originCZ
customs tariff number85363030
EAN4048879830454
eClass27141901
Packaging unit1

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.