MEANWELL RSD-60H-5 RSD-60H-5 MEANWELL DC-DC Enclosed converter, Input 40-160VDC, Output 5VDC / 12A, railway standard EN50155, 4.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

RSD-60H-5 MEANWELL DC-DC Enclosed converter, Input 40-160VDC, Output 5VDC / 12A, railway standard EN50155, 4..

RSD-60H-5

RSD-60H-5

MEANWELL

1 unit


Automation > DC/DC BOXES AND OPEN
RSD

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Details

Dc/DC converter Rail is a Regulated Isolated Output.

Converter for Railway applications, Industrial or Telecommunications.

Input range40-160Vcc(5.75 in-7Vcc for 1 second).

Output voltage5vdc.

Output intensity12A.

Power:60W.

Isolation input-output 4000Vcc.

Efficiency of the89%.

Operating temperature from-40up+70 ° C(see the curve derived in the technical data sheet). 85 ° c for 10 minutes with ventilation by conduction.

Dimensions (Width x Height x depth):128 x 60 x 25mm.

3 years of warranty.

Manufacturer: MEAN WELL.

This model has a hold time (hold-up time) to the output of10ms at full load.

It is a converter designed for railway applications, industrial or telecommunications.

Is certified with the regulations for railway EN50155 and EN45545-2 in front of the fire.

Can operate up to 55C at full load and 70 ° C at 60% load or 70 ° C ambient temperature with ventilation by driving without losses. Also supports a temperature range of more demanding level rail Tx to 85ºC ambient temperature for 10 minutes with ventilation by driving on a metal surface.

This converter semi-encapsulation has been designed for the most demanding applications at the level of vibration, temperature, and humidity. Has a low profile of only 25mm.

Its output is protected against short-circuits and overloads by limiting output current, this allows you to start loads with a high inrush.

Additional information

NameRSD-60H-5
Long Description

Dc/DC converter Rail is a Regulated Isolated Output.

Converter for Railway applications, Industrial or Telecommunications.

Input range40-160Vcc(5.75 in-7Vcc for 1 second).

Output voltage5vdc.

Output intensity12A.

Power:60W.

Isolation input-output 4000Vcc.

Efficiency of the89%.

Operating temperature from-40up+70 ° C(see the curve derived in the technical data sheet). 85 ° c for 10 minutes with ventilation by conduction.

Dimensions (Width x Height x depth):128 x 60 x 25mm.

3 years of warranty.

Manufacturer: MEAN WELL.

This model has a hold time (hold-up time) to the output of10ms at full load.

It is a converter designed for railway applications, industrial or telecommunications.

Is certified with the regulations for railway EN50155 and EN45545-2 in front of the fire.

Can operate up to 55C at full load and 70 ° C at 60% load or 70 ° C ambient temperature with ventilation by driving without losses. Also supports a temperature range of more demanding level rail Tx to 85ºC ambient temperature for 10 minutes with ventilation by driving on a metal surface.

This converter semi-encapsulation has been designed for the most demanding applications at the level of vibration, temperature, and humidity. Has a low profile of only 25mm.

Its output is protected against short-circuits and overloads by limiting output current, this allows you to start loads with a high inrush.

Country of OriginTaiwan
ManufacturerMEAN WELL
Product typeDc/DC converters
FormatBox
SubformatoGrid
ApplicationsRailway, Industrial, Telecommunications
SeriesRSD-60
StateRecommended Model
Warranty (Years)3,00
Height (mm)25.00
Width (mm)60.00
Long/Background128.00
Input range4:1
DC input Min40,00
DC input Max160,00
Input connectorScrew-Type
Output voltage5,00
Power (W)60,00
Peak Power (W)Sixty
Output connectorScrew-Type
Isolation (V)4.000,00
ApprovalsEC

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.