LOVATO ELECTRIC P1RB1NC20AC030 P1RB1NC20AC030 LOVATO RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION, 10KA. 2 MODULES, 1P+N TY.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

P1RB1NC20AC030 LOVATO RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION, 10KA. 2 MODULES, 1P+N TY..

P1RB1NC20AC030

10000

LOVATO ELECTRIC

1 Pcs.

RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION, 10KA. 2 MODULES, 1P+N - TYPE AC, 20A, 30mA RCBO 1P+N C 20A IDN 30MA 10KA Residual current circuit breaker with overcurrent protection, 10kA. 2 modules, 1P+N - type AC, 20A RESIDUAL CURRENT CIRCUIT BREAKER, 10KA. 2 MODULES, 1P+N TYPE AC, 20A, 30mA

Automation > Earth leakage circuit breaker
Miniature and residual circuit breakers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Lovato Electric residual current circuit breaker with overcurrent protection combines ground fault interruption with line overload safety. These dual-purpose devices are installed in control gear assemblies to prevent electrical hazards and equipment failures.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Disconnection characteristic (EF012587): Undelayed
  • Degree of protection (IP) (EF005474): IP20
  • Frequency (EF005455): 50/60 Hz
  • Leakage current type (EF002560): AC
  • Release characteristic (EF000889): C
  • Voltage type (EF000187): AC
  • Ambient temperature during operating (EF007515): -25 °C
  • Connectable conductor cross section solid-core (EF007337): 1 mm²
  • Anti-nuisance tripping version (EF009497): No
  • With interlocking device (EF007385): No
  • Concurrently switching neutral conductor (EF005997): Yes
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV
  • Number of poles (total) (EF008618): 2
  • Number of protected poles (EF005548): 1
  • Width in number of modular spacings (EF002950): 2
  • Pollution degree (EF002570): 2

More info

▲

P1RB1NC20AC030

Residual current circuit breaker with overcurrent protection, 10kA. 2 modules, 1P+N - type AC, 20A

Technical specifications

Type of product:
Residual current circuit breakers with overcurrent protection
Number of DIN modules:
2
Number of poles:
1P+N
Tripping curve:
C
Residual operation characteristic:
AC
Rated residual current I∆n [mA]:
30
Rated current In [A]:
20
Compliance:
IEC
Order codeP1RB1NC20AC030
Weight [g]205
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]115X040X080
Volume [cm³]368
Bar code [EAN13]8013975204443
HS Code85363030

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.