LOVATO ELECTRIC P1RB1NC10AC030 P1RB1NC10AC030 LOVATO RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION, 10KA. 2 MODULES, 1P+N TY.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

P1RB1NC10AC030 LOVATO RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION, 10KA. 2 MODULES, 1P+N TY..

P1RB1NC10AC030

10000

LOVATO ELECTRIC

1 Pcs.

RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION, 10KA. 2 MODULES, 1P+N - TYPE AC, 6A, 30mA RCBO 1P+N C 10A IDN 30MA 10KA Residual current circuit breaker with overcurrent protection, 10kA. 2 modules, 1P+N - type AC, 10A RESIDUAL CURRENT CIRCUIT BREAKER, 10KA. 2 MODULES, 1P+N AC TYPE, 10A, 30mA

Automation > Earth leakage circuit breaker
Miniature and residual circuit breakers

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Lovato Electric residual current circuit breaker with overcurrent protection, designated as P1RB1NC10AC030, is utilized within electrical enclosures to shield wiring systems from overload currents and insulation failures. The device automatically trips when current leakage or overcurrent thresholds are breached. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Disconnection characteristic (EF012587): Undelayed
  • Degree of protection (IP) (EF005474): IP20
  • Frequency (EF005455): 50/60 Hz
  • Leakage current type (EF002560): AC
  • Release characteristic (EF000889): C
  • Voltage type (EF000187): AC
  • Ambient temperature during operating (EF007515): -25 °C
  • Connectable conductor cross section solid-core (EF007337): 1 mm²
  • Anti-nuisance tripping version (EF009497): No
  • With interlocking device (EF007385): No
  • Concurrently switching neutral conductor (EF005997): Yes
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV
  • Number of poles (total) (EF008618): 2
  • Number of protected poles (EF005548): 1
  • Width in number of modular spacings (EF002950): 2
  • Pollution degree (EF002570): 2

More info

▲

P1RB1NC10AC030

Residual current circuit breaker with overcurrent protection, 10kA. 2 modules, 1P+N - type AC, 10A

Technical specifications

Type of product:
Residual current circuit breakers with overcurrent protection
Number of DIN modules:
2
Number of poles:
1P+N
Tripping curve:
C
Residual operation characteristic:
AC
Rated residual current I∆n [mA]:
30
Rated current In [A]:
10
Compliance:
IEC
Order codeP1RB1NC10AC030
Weight [g]205
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]115X040X080
Volume [cm³]368
Bar code [EAN13]8013975204405
HS Code85363010

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.