LOVATO ELECTRIC M1R00912400A7 M1R00912400A7 LOVATO DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH RESET PUSH BUTTON, W.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

M1R00912400A7 LOVATO DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH RESET PUSH BUTTON, W..

M1R00912400A7

00912400

LOVATO ELECTRIC

1 Pcs.

DIRECT-ON-LINE-STARTER, ENCLOSED WITH THERMAL OVERLOAD RELAY, WITH RESET PUSH BUTTON, WITH BF09/BF18 CONTACTOR, 10A MAX (3…4KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ DOL STARTER M1R 400/50-60 2,5-4A Direct-on-line-starter, enclosed with thermal overload relay, with RESET pushbutton, with BF09/BF18 contactor, 10A max (3...4kW at 400V), IP65. Contactor coil voltage 400VAC 50/60Hz DIRECT STARTER, WITH THERMAL RELAY IN INSULATED CASE, WITH RESET BUTTON, WITH BF09/BF18 CONTACTOR, 10A MAX (3...4KW AT 400V), IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ

Automation > Motor starter/Motor starter combination
Electromechanical starters - LOVATO ELECTRIC

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

M1R00912400A7

Direct-on-line-starter, enclosed with thermal overload relay, with RESET pushbutton, with BF09/BF18 contactor, 10A max (3...4kW at 400V), IP65. Contactor coil voltage 400VAC 50/60Hz

Technical specifications

Type of product:
Direct-on-line-starters
IEC operating current and power Ie (AC3) 400V [A/Kw]:
4A / 1.5kW
UL/CSA horsepower ratings 480V [HP]:
2
Type:
Enclosed with thermal overload relay
Type of coil:
AC coil
Type of pushbutton:
With reset push button
Contactor coil voltage:
400VAC 50/60HZ
Order codeM1R00912400A7
Weight [g]1000
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]206X092X170
Volume [cm³]3221.84
Bar code [EAN13]8013975158586
HS Code85371098

193.44 £


ETIM for M1R00912400A7 Low-voltage industrial controls and switchgear (EC001037)
Feature Name Feature Value
Degree of protection (NEMA) (EF011959) 4X
Type of motor starter (EF009598) Direct starter
Voltage type for actuating (EF008242) AC
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Type of electrical connection of main circuit (EF006819) Screw connection
Release class (EF006668) CLASS 10 A
Degree of protection (IP) (EF005474) IP65
Rated control supply voltage AC 60 Hz (EF003979) 400 V
Rated control supply voltage AC 50 Hz (EF003978) 400 V
Overload release current setting (EF002336) 2.5 A
Temperature compensated overload protection (EF009604) Yes
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
With fuse (EF006693) No
With short-circuit release (EF006691) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for SERCOS (EF006657) No
Suitable for rail mounting (EF003972) No
External reset possible (EF003426) Yes
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for LON (EF003017) No
Suitable for emergency stop (EF001433) No
With transformer (EF000278) No
Rated conditional short-circuit current, type 2, 230 V (EF009606) 50000 A
Rated conditional short-circuit current, type 2, 400 V (EF009605) 50000 A
Ambient temperature, upper operating limit (EF009603) 60 °C
Rated operation current at AC-3, 400 V (EF009602) 4 A
Rated operation power at AC-3, 230 V, 3-phase (EF009599) 2.2 kW
Number of indicator lights (EF001965) 0
Rated operation current Ie (EF001443) 4 A
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Rated operation power at AC-3, 400 V (EF001364) 1.5 kW
Depth (EF000049) 148 mm
Height (EF000040) 202 mm
Width (EF000008) 88 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.