LOVATO ELECTRIC BFC18T4A230 BFC18T4A230 LOVATO CHANGEOVER CONTACTOR ASSEMBLY 32A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

BFC18T4A230 LOVATO CHANGEOVER CONTACTOR ASSEMBLY 32A

BFC18T4A230

10000

LOVATO ELECTRIC

1 Pcs.

CHANGEOVER CONTACTOR ASSEMBLY 32A Changeover assembly, AC coil, side mount mechanical interlock with 2NC contacts, 32A AC1 in AC. Coil voltage 230VAC 50/60Hz CHANGEOVER CONTACTOR ASSEMBLY, AC COIL, SIDE MOUNT MECHANICAL INTERLOCK WITH 2NC CONTACTS, 32A AC1 IN AC. COIL VOLTAGE 230VAC 50/60HZ

Automation > Motor starter/Motor starter combination
Electromechanical starters - LOVATO ELECTRIC

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

BFC18T4A230

Changeover assembly, AC coil, side mount mechanical interlock with 2NC contacts, 32A AC1 in AC. Coil voltage 230VAC 50/60Hz

Technical specifications

Type of product:
Changeover contactor assemblies
Type:
Side mount mechanical interlock
Type of coil:
AC coil
Contactor coil voltage:
230VAC 50/60HZ
Order codeBFC18T4A230
Weight [g]0.786
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]126X092X085
Volume [cm³]985.32
Bar code [EAN13]8013975268476
HS Code85365080

ETIM for BFC18T4A230 Low-voltage industrial controls and switchgear (EC001037)
Feature Name Feature Value
Degree of protection (NEMA) (EF011959) Other
Type of motor starter (EF009598) Other
Voltage type for actuating (EF008242) AC
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Type of electrical connection of main circuit (EF006819) Screw connection
Degree of protection (IP) (EF005474) IP20
Rated control supply voltage AC 60 Hz (EF003979) 230 V
Rated control supply voltage AC 50 Hz (EF003978) 230 V
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
With fuse (EF006693) No
With short-circuit release (EF006691) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for SERCOS (EF006657) No
Suitable for rail mounting (EF003972) Yes
External reset possible (EF003426) No
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for LON (EF003017) No
Suitable for emergency stop (EF001433) No
With transformer (EF000278) No
Rated conditional short-circuit current, type 2, 230 V (EF009606) 50000 A
Rated conditional short-circuit current, type 2, 400 V (EF009605) 50000 A
Ambient temperature, upper operating limit (EF009603) 70 °C
Number of indicator lights (EF001965) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Depth (EF000049) 81 mm
Height (EF000040) 81 mm
Width (EF000008) 100 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.