646117 LEGRAND PDU LK NO 0U 3P32A 36C13 6C19
646117
646117
LEGRAND
1 Pcs.
PDU LK NO 0U 3P32A 36C13 6C19
Smart PDU, Metered (Node Version), Zero-U, Three-Phase 32A, 36 HD C13 Sockets + 6 C19 Sockets, with Cable Lock
PDU HD MEASURED NODE 0U, 3 PHASES 32A, 36 C13+6 C19 BLOCKING JACKS, IEC 60309
Automation > Power distribution unit (PDU)
PDU
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Legrand 646117 is a PDU LK NO 0U 3P32A 36C13 6C19 configured to serve as an advanced rack power distribution unit. High-capacity power strips ensure stable energy delivery and monitoring for demanding server room installations.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- With LED indication (EF005950): Yes
- Number of socket outlets Swiss standard type 25 (EF011979): 0
- Number of socket outlets Swiss standard type 23 (EF011978): 0
- Number of socket outlets Swiss standard type 15 (EF011977): 0
- Temperature measurement (EF006229): Yes
- With mounting material (EF006009): Yes
- Number of socket outlets Swiss standard type 13 (EF011975): 0
- Number of USB connections (EF008500): 2
- Over voltage category (EF006785): 2
- Control function (EF002685): No
- With surge protection module (EF017068): No
- Number of socket outlets British Standard BS 1363 (EF012037): 0
- Mounting direction (EF003824): Vertical
- With display (EF000458): Yes
- Electrical connection (EF003701): Connecting cord with plug
- Cable length (EF000536): 3 m
More info
▲| Mounting Dimension (Standardized) | Metric |
|---|---|
| Mounting Size | 1722 mm |
| Assembly Direction | Vertical |
| Electrical connection | Wired connector |
| Running the electrical connection | EEC 32 A |
| Number of phases | 3 |
| Cable length | 3 m |
| Number of circuit breakers | 6 |
| Number of sockets with EEC 7/3 protective contact (type F) | 0 |
| Number of French Standard Sockets (Type E) | 42 |
| Number of sockets C13 | 36 |
| Number of sockets C19 | 6 |
| Number of C20 sockets | 0 |
| Number of sockets according to British standard (BS1363) | 0 |
| Number of Swiss Standard Type 13 sockets | 0 |
| Number of Swiss Standard Type 15 Power Sockets | 0 |
| Number of Swiss Standard Type 23 sockets | 0 |
| Number of Swiss Standard Type 25 sockets | 0 |
| Number of RJ45 connectors | 2 |
| Number of USB connections | 2 |
| Number of other power outlets | 0 |
| Longitude | 1710 mm |
| Width | 52 mm |
| Depth | 91.4 mm |
| Nominal intensity | 32 A |
| Supply voltage | 415 V |
| With surge protection module | No |
| Surge Category | 2 |
| EMC Filter | No |
| Switchable | No |
| With measuring device | Yes |
| Control function | No |
| SNMP | Yes |
| With screen | Yes |
| Evaluation | Other |
|---|---|
| With LED indicator | Yes |
| Fused | No |
| Ammeter | Yes |
| Temperature Measurement | Yes |
| Includes mounting hardware | Yes |
| Colour | Black |
| Impact resistance | Not applicable |
| Protection Class (IP) | IP40 |
| Operating Temperature | -5-60 °C |
| Storage temperature | -20-70 °C |
| Type of voltage | AC |
| Nominal current | 32-32 A |
| frequency | 50-60 Hz |
| Display of markings on the connection terminals | No |
| RAL number | 9017 |
| Connection Method | Screw-on terminal |
| Terminal capacity | 6-6 mm² |
| Connection Cable Type | Flexible |
| Core cross-section | 6-6 mm² |
| Maximum cable entry diameter | 19 mm |
| Number of Circuit Breakers | 6 |
| Number of residual current circuit breakers | 0 |
| Number of CX sockets | 0 |
| Connected Object | Yes |
| Method of operation | Red, Zigbee |
| App download platform | Not applicable |
| With voice command | No |
| Programmable | No |
| Connection Protocol Interoperability | Yes |
| Possibility of connection via Internet box | Yes |
| Programming medium | Web software |
| Product usage function | Power Distribution |