View larger
Images are for illustrative purposes only. Please refer to data sheet for details
423114 LEGRAND DPX3250HP MAG+DIF 4P 125A 50KA
423114
423114
LEGRAND
1 Pcs.
DPX3250HP MAG+DIF 4P 125A 50KA
DPX³ 250 HP 4 Pole 125A Thermal Magnetic MCCB with Earth Leakage Module 50kA
DPX³ 250 HP molded case switch - circuit breaker dif - 4P - 50kA - 125A
Automation > Power circuit-breaker for trafo/generator/installation protection
DPX3 MOLDED BOX
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A LEGRAND DPX3250HP MAG+DIF 4P 125A 50KA circuit breaker integrates both thermal-magnetic trip mechanisms and differential protection to shield electrical circuits from overloads, short circuits, and earth leakage hazards.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Degree of protection (IP) (EF005474): IP30
- Adjustment range undelayed short-circuit release (EF007131): 625 A
- Integrated earth fault protection (EF007296): Yes
- With integrated under voltage release (EF001390): No
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- Device construction (EF008240): Built-in device fixed built-in technique
- Number of poles (EF001391): 4
- Type of electrical connection of main circuit (EF006819): Bolt connection
- Overload release current setting (EF002336): 100 A
- Motor drive integrated (EF006697): No
- Type of control element (EF006976): Toggle
- Rated permanent current Iu (EF001389): 125 A
- With switched-off indicator (EF007006): Yes
- Motor drive optional (EF007386): Yes
- Position of connection for main current circuit (EF006671): Front
- Rated voltage (EF003977): 230 V
More info
▲| Rated permanent current Iu | 125 A |
|---|---|
| Rated voltage | 230-690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz | 50 kA |
| Overload release current setting | 100-125 A |
| Adjustment range undelayed short-circuit release | 625-1250 A |
| Device construction | Built-in device fixed built-in technique |
| Integrated earth fault protection | Yes |
| Type of electrical connection of main circuit | Bolt connection |
| Suitable for DIN rail (top hat rail) mounting | No |
| DIN rail (top hat rail) mounting optional | No |
| Number of auxiliary contacts as normally closed contact | 0 |
| Number of auxiliary contacts as normally open contact | 0 |
| Number of auxiliary contacts as change-over contact | 3 |
| With switched-off indicator | Yes |
| With integrated under voltage release | No |
| Number of poles | 4 |
| Position of connection for main current circuit | Front side |
| Type of control element | Wing knob |
| Complete device with protection unit | Yes |
| Motor drive integrated | No |
|---|---|
| Motor drive optional | Yes |
| Degree of protection (IP) | IP30 |
| Width | 140 mm |
| Height | 165 mm |
| Depth | 112 mm |
| degree of impact strength (IK) | Not applicable |
| Operating / setting temperature | -5-70 °C |
| Storage temperature | -25-85 °C |
| Voltage type | AC |
| Frequency | 50-60 Hz |
| Electric supplying direction | Not applicable |
| Terminal marking indication | No |
| Colour | Grey |
| RAL-number | 7035 |
| Halogen free | Yes |
| Terminals capacity | 2.5-120 mm² |
| Cable nature for connection | Flexible or rigid |
| Label space/information surface | No |