LEGRAND 412280 412280 LEGRAND LIMIT SOBRET T1 35KA 1P +SD View larger
Images are for illustrative purposes only. Please refer to data sheet for details

412280 LEGRAND LIMIT SOBRET T1 35KA 1P +SD

412280

412280

LEGRAND

1 Pcs.

LIMIT SOBRET T1 35KA 1P +SD SPD - high risk level installation. - T1+T2 - limp 35 kA/pole - 440 V~(IT) -plug-in -1P Surge limiter T1 - very high risk inst. - Iimp 35kA/pole - 1P

Automation > Surge protection device for power supply systems
MOTOR CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Legrand 412280 limit sobret t1 35ka 1p +sd functions as a robust type 1 surge protection device designed to handle high energy surges directly at the main building entry point. Devices in this category intercept direct lightning strikes and heavy switching pulses, shunting destructive currents safely into the ground network.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • System configuration TN-C-S (EF009933): Yes
  • Degree of protection (IP) (EF005474): IP20
  • Nominal voltage AC (EF004220): 400 V
  • System configuration TN-S (EF009930): No
  • Construction size (EF002566): 2 modular spacing
  • System configuration other (EF009932): No
  • Mounting method (EF000003): DIN rail (top hat rail) 35 mm
  • System configuration TT (EF009931): No
  • Signalling at the device (EF004241): Optic
  • Number of conductors (without earthing) (EF001148): 1
  • Voltage protection level (EF003525): 2.5 kV
  • System configuration IT (EF009927): Yes
  • System configuration TN-C (EF009929): Yes
  • System configuration TN (EF009928): Yes
  • Max. continuous voltage AC (EF004198): 440 V
  • Integrated backup fuse (EF008797): No

More info

▲
  • Pack (number of units)1
  • Volume (dm3)0.369
  • Weight (g)420.00
Product characteristics
SPDs for high risk level installations
  • SPDs for big installations with external lightning protection (LPS) and for high risk level installations according to EN/IEC 62305 standards
  • SPDs with plug-in modules and status indicators:
    • Green: SPD operational
    • Red: plug-in modules to be replaced
T1 + T2 - Iimp 35 kA/pole - 440V~ (IT) - Plug-in
  • Up: 2.5 kV - Uc: 440 V~
  • Earthing systems: TT, TNC, TNS, IT
  • Recommended MCCB: DPX³ 160 - 80 A
  • Number of poles : 1P
  • Itotal (10/350) : 35 kA
  • Remote status monitoring (FS contact) : Yes
  • Number of modules : 2
General characteristics
Class I + II (T1+T2) low voltage SPDs
  • Protection against transient overvoltagess for 230/400 V~ power networks (50/60 Hz).
  • SPDs compliant with EN/IEC 61643-11 standards
  • Recommended for main distribution boards
  • Class I+II (T1+T2) : SPDs tested and specified according to both T1 and T2 test classes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.