Request QuoteProduct Overview
Legrand 412274 combined Type 1 and Type 2 surge limiters are designed to absorb high-energy lightning currents and protect electrical distribution equipment from catastrophic transient overvoltages. They mount neatly onto standard DIN rails in electrical enclosures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- System configuration TN-C-S (EF009933): Yes
- Degree of protection (IP) (EF005474): IP20
- Nominal voltage AC (EF004220): 230 V
- System configuration TN-S (EF009930): No
- Construction size (EF002566): 2 modular spacing
- System configuration other (EF009932): No
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
- System configuration TT (EF009931): Yes
- Signalling at the device (EF004241): Optic
- Number of conductors (without earthing) (EF001148): 2
- System configuration IT (EF009927): No
- System configuration TN-C (EF009929): Yes
- System configuration TN (EF009928): Yes
- Max. continuous voltage AC (EF004198): 320 V
- Voltage protection level N-PE (EF008796): 1.5 kV
- Integrated backup fuse (EF008797): No
More info
▲- Pack (number of units)1
- Volume (dm3)0.369
- Weight (g)249.00
- SPDs with plug-in modules and status indicators:
- Green: SPD operational
- Orange: plug-in modules to be replaced
- Earthing systems: TT, TNC, TNS
- For general protection of big installations and protection of small installations with external lightning protection (LPS).
- Up: 1.5 kV - Imax: 60 kA/pole - Uc: 320 V~
- Recommended MCB: DX³ 63 A - C curve
- 1P+N and 3P+N: L-N and N-PE protection modes (common and differential modes), the N pole being protected by encapsulated spark gaps. Also called 1+1 and 3+1
- Number of poles : 1P+N
- Neutral position : Left
- Itotal (10/350) : 25 kA
- Remote status monitoring (FS contact) : Yes
- Number of modules : 2
- Protection against transient overvoltagess for 230/400 V~ power networks (50/60 Hz).
- SPDs compliant with EN/IEC 61643-11 standards
- Recommended for main distribution boards
- Class I+II (T1+T2) : SPDs tested and specified according to both T1 and T2 test classes