LEGRAND 412242 412242 LEGRAND LIMIT OVERT T2 40KA 3P + SD View larger
Images are for illustrative purposes only. Please refer to data sheet for details

412242 LEGRAND LIMIT OVERT T2 40KA 3P + SD

412242

412242

LEGRAND

1 Pcs.

LIMIT OVERT T2 40KA 3P + SD SPD - T2 - Imax 40 kA/pole - 3P Low voltage surge arrester type T2 Imax 40kA/pole - 3P

Automation > Surge protection device for power supply systems
MOTOR CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Legrand limit overt t2 40ka 3p + sd, designated by part number 412242, provides reliable surge suppression performance to protect commercial and industrial power distribution architecture. Such modular surge protection devices are routinely installed inside electrical enclosures to mitigate transient voltage surges.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • System configuration TN-C-S: Yes
  • Degree of protection (IP): IP20
  • Nominal voltage AC: 230 V
  • System configuration TN-S: No
  • Construction size: 3 modular spacing
  • System configuration other: No
  • Mounting method: DIN rail (top hat rail) 35 mm
  • System configuration TT: No
  • Signalling at the device: Optic
  • Number of conductors (without earthing): 3
  • Voltage protection level: 1.7 kV
  • System configuration IT: No
  • System configuration TN-C: Yes
  • System configuration TN: Yes
  • Max. continuous voltage AC: 320 V
  • Integrated backup fuse: No

More info

▲
  • Pack (number of units)1
  • Volume (dm3)0.521
  • Weight (g)329.00
Product characteristics
T2 SPDs
  • SPDs with plug-in modules and status indicators:
    • Green: SPD operational
    • Orange: plug-in modules to be replaced
T2 - Imax 40 kA/pole
  • SPDs recommended for power installations
  • Up: 1.7 kV - In: 20 kA/pole - Uc: 320 V~
  • Earthing systems : TT, TNC, TNS
  • Recommended MCB: DX³ 25 A - C curve
  • Number of poles : 3P
  • Remote status monitoring (FS contact) : Yes
  • Number of modules : 3
General characteristics
Class II (T2) low voltage SPDs
  • Protection against transient overvoltagess for 230/400 V~ power networks (50/60 Hz). SPDs compliant with EN/IEC 61643-11 standards
  • Recommended for distribution boards

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.