Legrand 411792 DIFFERENTIAL DX3 4/80/500 TO units serve as protective differential protection modules integrated into industrial distribution networks to disconnect hazardous earth faults. By continuously monitoring circuit balance, these components prevent prolonged leakage currents from triggering electrical fires. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Explosion-proof (EF004663): No
- Connectable conductor cross section solid-core (EF007337): 0.75 mm²
- Frequency (EF005455): 50 Hz
- Selective protection (EF002561): No
- Short-circuit breaking capacity (Icw) (EF002562): 10 kA
- Ambient temperature during operating (EF007515): -25 °C
- Degree of protection (IP) (EF005474): IP20
- Leakage current type (EF002560): A
- Voltage type (EF000187): AC
- Additional equipment possible (EF008148): Yes
- Mounting method (EF000003): DIN rail
- Surge current capacity (EF002564): 0.25 kA
- Number of poles (EF001391): 4
- Short-time delayed tripping (EF003604): No
- Rated fault current (EF002358): 0.5 A
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
More info
▲| Number of poles | 4 |
|---|---|
| Rated voltage | 400 V |
| Rated current | 80 A |
| Rated fault current | 0.5 A |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 4 kV |
| Mounting method | DIN rail |
| Leakage current type | A |
| Selective protection | No |
| Short-time delayed tripping | No |
| Short-circuit breaking capacity (Icw) | 10 kA |
| Surge current capacity | 0.25 kA |
| Voltage type | AC |
| With interlocking device | Yes |
| Frequency | 50 Hz |
| Additional equipment possible | Yes |
| Degree of protection (IP) | IP20 |
| Width in number of modular spacings | 4 |
| Built-in depth | 44 mm |
| Ambient temperature during operating | -25-60 °C |
|---|---|
| Pollution degree | 2 |
| Connectable conductor cross section multi-wired | 0.75-35 mm² |
| Connectable conductor cross section solid-core | 0.75-50 mm² |
| Colour | Grey |
| RAL-number (similar) | 7035 |
| Explosion-proof | No |
| Width | 71.2 mm |
| Height | 83 mm |
| Depth | 77.8 mm |
| degree of impact strength (IK) | IK04 |
| Storage temperature | -40-70 °C |
| Electric supplying direction | By the top or bottom |
| Terminal marking indication | Yes |
| Stress test conformity (1000V) | Yes |
| Halogen free | Yes |
| Connection type | Screwed terminal , Busbar and cable |
| Label space/information surface | Yes |