LEGRAND 411735 411735 LEGRAND DIFFERENTIAL DX3 4/80/500 AC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

411735 LEGRAND DIFFERENTIAL DX3 4/80/500 AC

411735

411735

LEGRAND

1 Pcs.

DIFFERENTIAL DX3 4/80/500 AC DX³-ID 4 Pole 80A AC Type RCD 500mA Neutral on Right-Hand Side DX³ Differential Switch - 4P - 400V~ - 80A - AC Type - 500mA - 4mod

Automation > Residual current circuit breaker (RCCB)
TERTIARY CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Legrand 411735 is a DX3 differential residual current device utilized in electrical panel boards to detect earth fault currents and protect users from electric shock. These units monitor phase and neutral current balances, tripping instantly when leakage exceeds the rated threshold to disconnect vulnerable circuits.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Explosion-proof (EF004663): No
  • Connectable conductor cross section solid-core (EF007337): 0.75 mm²
  • Frequency (EF005455): 50 Hz
  • Selective protection (EF002561): No
  • Short-circuit breaking capacity (Icw) (EF002562): 10 kA
  • Ambient temperature during operating (EF007515): -25 °C
  • Degree of protection (IP) (EF005474): IP20
  • Leakage current type (EF002560): AC
  • Voltage type (EF000187): AC
  • Additional equipment possible (EF008148): Yes
  • Mounting method (EF000003): DIN rail
  • Surge current capacity (EF002564): 0.25 kA
  • Number of poles (EF001391): 4
  • Short-time delayed tripping (EF003604): No
  • Rated fault current (EF002358): 0.5 A
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV

More info

▲
Conform to IEC 61008-1 * AC type : detect AC component faults * A type : detect AC and DC component faults Enhanced immunity to unwanted tripping in disturbed environments Can be equipped with DX3 auxiliaries and accessories
Number of poles4
Rated voltage400 V
Rated current80 A
Rated fault current0.5 A
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Mounting methodDIN rail
Leakage current typeAC
Selective protectionNo
Short-time delayed trippingNo
Short-circuit breaking capacity (Icw)10 kA
Surge current capacity0.25 kA
Voltage typeAC
With interlocking deviceYes
Frequency50 Hz
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings4
Built-in depth44 mm
Ambient temperature during operating-25-60 °C
Pollution degree2
Connectable conductor cross section multi-wired0.75-35 mm²
Connectable conductor cross section solid-core0.75-50 mm²
ColourGrey
RAL-number (similar)7035
Explosion-proofNo
Width71.2 mm
Height83 mm
Depth77.8 mm
degree of impact strength (IK)IK04
Storage temperature-40-70 °C
Electric supplying directionBy the top or bottom
Terminal marking indicationYes
Stress test conformity (1000V)Yes
Halogen freeYes
Connection typeScrewed terminal , Busbar and cable
Label space/information surfaceYes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.