LEGRAND 411240 411240 LEGRAND MAGNET DIFFER DX3 4P 300mA C20 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

411240 LEGRAND MAGNET DIFFER DX3 4P 300mA C20

411240

411240

LEGRAND

1 Pcs.

MAGNET DIFFER DX3 4P 300mA C20 RCBO - DX³ 6000 -10 kA -4P-400 V~ -20 A -300 mA -A type Differential circuit breaker DX³ 6000/10kA curve C - 4P - 20A-300mA - Type A

Automation > Earth leakage circuit breaker
TERTIARY CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Legrand magnet differential DX3, identified by part number 411240, is a multi-pole residual current device used to detect earth fault currents and protect electrical installations against insulation failures and leakage. These modules mount onto DIN rails within industrial control panels to disconnect power safely when thresholds are exceeded.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Frequency (EF005455): 50 Hz
  • Degree of protection (IP) (EF005474): IP20
  • Leakage current type (EF002560): A
  • Voltage type (EF000187): AC
  • Concurrently switching neutral conductor (EF005997): Yes
  • Surge current capacity (EF002564): 0.25 kA
  • Anti-nuisance tripping version (EF009497): No
  • Rated fault current (EF002358): 0.3 A
  • Number of protected poles (EF005548): 4
  • Built-in depth (EF000218): 44 mm
  • Number of poles (total) (EF008618): 4
  • Pollution degree (EF002570): 2
  • Width in number of modular spacings (EF002950): 4
  • With interlocking device (EF007385): Yes
  • Rated current (EF000227): 20 A
  • Current limiting class (EF002568): 3

More info

▲
  • Pack (number of units)1
  • Volume (dm3)0.701
  • Weight (g)474.00
Product characteristics
4-pole - 400 V~
  • 4-module RCBOs are compatible with prong-type and fork type supply busbars
  • 7-module RCBOs are compatible with prong-type supply busbars only
A Type 300 mA
  • C curve
  • Nominal rating In : 20 A
  • Number of modules : 4
General characteristics
RCBOs DX³ 6000 - 10 kA - residual current circuit breakers from 10 A to 63 A - AC, A and F types
  • Conform to IEC 61009-1, IEC 62423 (F type)
  • Voltage independent tripping
  • Breaking capacity:
    • 6000 - IEC 61009-1 - 10 kA / IEC 60947-2 for single pole + neutral, 2 and 4-pole
  • AC type : detect AC component faults
  • A type : detect AC and DC component faults
  • F type (High immunity) : detect AC and pulsating DC residual currents. Enhanced immunity to unwanted tripping in disturbed environments. Detection of high frequency fault currents
  • Can be equipped with DX³ signalling and remote tripping auxiliaries and motorised controls

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.