LEGRAND 411238 411238 LEGRAND MAGNET DIFFER DX3 4P 300mA C10 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

411238 LEGRAND MAGNET DIFFER DX3 4P 300mA C10

411238

411238

LEGRAND

1 Pcs.

MAGNET DIFFER DX3 4P 300mA C10 RCBO - DX³ 6000 -10 kA -4P-400 V~ -10 A -300 mA -A type Differential circuit breaker DX³ 6000/10kA curve C - 4P - 10A-300mA - Type A

Automation > Earth leakage circuit breaker
TERTIARY CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Safeguarding electrical systems against overcurrents and residual current issues, the Legrand magnetic differential switch (part 411238) offers four-pole protection. Units of this type are deployed within comprehensive electrical distribution boards to maintain structural safety and prevent fault propagation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Frequency (EF005455): 50 Hz
  • Degree of protection (IP) (EF005474): IP20
  • Leakage current type (EF002560): A
  • Voltage type (EF000187): AC
  • Concurrently switching neutral conductor (EF005997): Yes
  • Surge current capacity (EF002564): 0.25 kA
  • Anti-nuisance tripping version (EF009497): No
  • Rated fault current (EF002358): 0.3 A
  • Number of protected poles (EF005548): 4
  • Built-in depth (EF000218): 44 mm
  • Number of poles (total) (EF008618): 4
  • Pollution degree (EF002570): 2
  • Width in number of modular spacings (EF002950): 4
  • With interlocking device (EF007385): Yes
  • Rated current (EF000227): 10 A
  • Current limiting class (EF002568): 3

More info

▲
  • Pack (number of units)1
  • Volume (dm3)0.701
  • Weight (g)471.00
Product characteristics
4-pole - 400 V~
  • 4-module RCBOs are compatible with prong-type and fork type supply busbars
  • 7-module RCBOs are compatible with prong-type supply busbars only
A Type 300 mA
  • C curve
  • Nominal rating In : 10 A
  • Number of modules : 4
General characteristics
RCBOs DX³ 6000 - 10 kA - residual current circuit breakers from 10 A to 63 A - AC, A and F types
  • Conform to IEC 61009-1, IEC 62423 (F type)
  • Voltage independent tripping
  • Breaking capacity:
    • 6000 - IEC 61009-1 - 10 kA / IEC 60947-2 for single pole + neutral, 2 and 4-pole
  • AC type : detect AC component faults
  • A type : detect AC and DC component faults
  • F type (High immunity) : detect AC and pulsating DC residual currents. Enhanced immunity to unwanted tripping in disturbed environments. Detection of high frequency fault currents
  • Can be equipped with DX³ signalling and remote tripping auxiliaries and motorised controls

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.