LEGRAND 410015 410015 LEGRAND MAGNET DX3 36kA C 2P 80A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

410015 LEGRAND MAGNET DX3 36kA C 2P 80A

410015

410015

LEGRAND

1 Pcs.

MAGNET DX3 36kA C 2P 80A Circuit breaker DX3 36kA - 2P - 230/400V~ - 80 A - curve C DX³ Circuit Breaker 36kA - 2P - 230/400V~ - 80A - C curve

Automation > Miniature circuit breaker (MCB)
INDUSTRIAL CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Providing heavy-duty fault interruption, the 410015 LEGRAND MAGNET DX3 36kA C 2P 80A is a high-capacity miniature circuit breaker built for demanding electrical distribution networks. Such circuit breakers protect critical power lines and connected capital equipment from severe overcurrent damage.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Explosion-proof (EF004663): No
  • Connectable conductor cross section solid-core (EF007337): 6 mm²
  • Ambient temperature during operating (EF007515): -25 °C
  • Degree of protection (IP) (EF005474): IP20
  • Concurrently switching neutral conductor (EF005997): No
  • Voltage type (EF000187): AC
  • Additional equipment possible (EF008148): Yes
  • Rated impulse withstand voltage Uimp (EF011980): 6 kV
  • Number of protected poles (EF005548): 2
  • Frequency (EF000416): 50 Hz
  • Built-in depth (EF000218): 47 mm
  • Number of poles (total) (EF008618): 2
  • Pollution degree (EF002570): 3
  • Width in number of modular spacings (EF002950): 3
  • Rated insulation voltage Ui (EF001366): 500 V
  • Connectable conductor cross section multi-wired (EF007343): 6 mm²

More info

▲

Product features

Bipolar 230/400 V~ - Curve C - nominal Intensity: 80 - Number of modules: 3

General characteristics

MCB DX3 - 36 kA - breakers circuit - curve C - protection of the outputs - breaking capacity: 36 kA - UNE-en 60947-2 - 400 V~ - Support the auxiliary and all of the controllers-motorized - Connection: top entry and bottom exit for terminals with screws - automatic 2P/3P, and 4P are associated to the blocks of differential adaptive

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.