LEGRAND 409229 409229 LEGRAND MAGNET DX3 10/16kA C 2P 100A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

409229 LEGRAND MAGNET DX3 10/16kA C 2P 100A

409229

409229

LEGRAND

1 Pcs.

MAGNET DX3 10/16kA C 2P 100A DX³ 10000A 2 Pole 100A MCB C Curve 16kA DX³ 10000/16kA Circuit Breaker - 2P - 230/400V~ - 100A - C curve

Automation > Miniature circuit breaker (MCB)
INDUSTRIAL CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

409229 LEGRAND MAGNET DX3 10/16kA C 2P 100A provides reliable magnetic and thermal circuit protection within electrical distribution frameworks, interrupting high fault currents safely. Heavy-duty circuit protection devices are standard in industrial facilities to prevent catastrophic electrical failures and equipment damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Explosion-proof (EF004663): No
  • Connectable conductor cross section solid-core (EF007337): 6 mm²
  • Ambient temperature during operating (EF007515): -25 °C
  • Degree of protection (IP) (EF005474): IP20
  • Concurrently switching neutral conductor (EF005997): No
  • Voltage type (EF000187): AC
  • Additional equipment possible (EF008148): Yes
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV
  • Number of protected poles (EF005548): 2
  • Frequency (EF000416): 50 Hz
  • Built-in depth (EF000218): 44 mm
  • Number of poles (total) (EF008618): 2
  • Pollution degree (EF002570): 2
  • Width in number of modular spacings (EF002950): 3
  • Rated insulation voltage Ui (EF001366): 500 V
  • Connectable conductor cross section multi-wired (EF007343): 6 mm²

More info

Conform to IEC 60898-1 Breaking capacity 10000 - IEC 60898-1 - 400 VA 16 kA - IEC 60947-2 - 400 VA Can be equipped with DX3 auxiliaries and accessories
Built-in depth44 mm
Release characteristicC
Number of poles (total)2
Number of protected poles2
Rated current100 A
Rated voltage400 V
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V32 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16 kA
Frequency50-60 Hz
Flush-mounted installationYes
Concurrently switching neutral conductorNo
Pollution degree2
Additional equipment possibleYes
Width in number of modular spacings3
Degree of protection (IP)IP20
Ambient temperature during operating-25-70 °C
Connectable conductor cross section multi-wired6-50 mm²
Connectable conductor cross section solid-core6-70 mm²
Explosion-proofNo
Width35.4 mm
Height94.8 mm
Depth77.8 mm
degree of impact strength (IK)IK02
Storage temperature-40-70 °C
Electric supplying directionBy the top or bottom
ColourGrey
RAL-number7035
Halogen freeYes
Connection typeScrewed terminal
Label space/information surfaceYes
Mounting methodDIN rail

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.