LEGRAND 406285 406285 LEGRAND BATTERY FOR 406284 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

406285 LEGRAND BATTERY FOR 406284

406285

406285

LEGRAND

1 Pcs.

BATTERY FOR 406284 Replacement battery DX³ - for stand alone release Cat. No. 4 062 87 Recharge battery for standalone trigger ref. 4 062 87

Automation > Auxiliary device for distribution board devices
TERTIARY CIRCUIT BREAKERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A 406285 LEGRAND BATTERY FOR 406284 provides backup power storage to maintain operational continuity and trip readiness in compatible modular control and protection devices during utility interruptions.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Number of fault-signal switches (EF007613): 0
  • Number of contacts as change-over contact (EF008257): 0
  • Width in number of modular spacings (EF002950): 0.5
  • Suitable for max. current main contact unit (EF008730): 125 A
  • Voltage type (EF000187): DC
  • Number of contacts as normally closed contact (EF008255): 0
  • Number of contacts as normally open contact (EF008256): 0
  • With auto test for earth leakage function (EF008727): No
  • Rated voltage (EF000228): 3 V

More info

▲
  • Pack (number of units)1
  • Volume (dm3)0.219
  • Weight (g)36.00
Product characteristics
Remote tripping auxiliaries
  • To fit on the left-hand side of DX³ and TX³ devices
  • Maximum 1 remote tripping auxiliary per device
  • Allow insertion of the supply busbar
  • No tool required for joining together the auxiliary and the main device.
  • For MCBs, RCBOs, RCCBs and remote trip isolating switches
Autonomous shunt trip for N/C push-button
  • 230 VA
  • For remote tripping with positive security on a control circuit via a N/C push-button or emergency stop. Does not trigger its associated device in case of mains power failure (the trigger occurs only after a deliberate action of a N/C push-button).
  • Supplied with battery
  • Mimimum working reserve: 60 hours (for remote tripping even if there is no supply voltage)
  • Spare battery for autonomous shunt trip Cat.No 4 062 87
General characteristics
Signalling, remote tripping auxiliaries and motorised controls DX³

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.