LEGRAND 404937 404937 LEGRAND COMB UNIPOLAR 57 MOD View larger
Images are for illustrative purposes only. Please refer to data sheet for details

404937 LEGRAND COMB UNIPOLAR 57 MOD

404937

404937

LEGRAND

10 Pcs.

COMB UNIPOLAR 57 MOD Legrand Insulated Busbar 57 Way 1 Pole Units Universal unipolar feeding comb - L. 1m

Automation > Phase busbar
SPLITTERS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Legrand 404937 comb unipolar power distribution comb simplifies the interconnection of single-phase modular devices in electrical switchboards. By replacing individual wire jumpers, this busbar ensures a clean installation, consistent spacing, and secure electrical contact. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Suitable for devices with auxiliary switch (EF007217): No
  • Suitable for devices with N-conductor (EF007218): Yes
  • Module width (EF007504): 17.7 mm
  • Number of phases (EF000351): 1
  • Width in number of modular spacings (EF002950): 57
  • Conditioned rated short-circuit current Iq (EF001444): 0.63 kA
  • Max. rated operation voltage Ue (EF007357): 400 V
  • Rated permanent current Iu (EF001389): 63 A
  • Rated surge voltage (EF002993): 2 kV
  • Type of electric connection (EF003961): Pin
  • Suitable for number of devices (EF007241): 57
  • Rated short-time withstand current lcw (EF007050): 1.92 kA
  • Number of poles (EF001391): 1
  • Can be cut to size (EF015250): Yes
  • Insulated (EF000019): Yes
  • Length (EF001438): 1008 mm

More info

Supply busbars For 57 single pole units1 Reversible blue/black
Depth4 mm
Number of phases1
Number of poles1
Suitable for number of devices57
Module width17.7 mm
Cross section16 mm²
Length1008 mm
Can be cut to sizeYes
Width in number of modular spacings57
Rated permanent current Iu63 A
Type of electric connectionPin
InsulatedYes
Rated surge voltage2 kV
Conditioned rated short-circuit current Iq0.63 kA
Max. rated operation voltage Ue400 V
Rated short-time withstand current lcw1.92 kA
Suitable for devices with N-conductorYes
Suitable for devices with auxiliary switchNo
ColourOther
Height21 mm
Operating / setting temperature-20-50 °C
Storage temperature-40-70 °C
Busbar type suppliedHorizontal

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.