View larger
Images are for illustrative purposes only. Please refer to data sheet for details
044266 LEGRAND TRANSFORMER 230-400V/115-230V 400VA
044266
044266
LEGRAND
1 Pcs.
TRANSFORMER 230-400V/115-230V 400VA
Legrand Safety Isolating Transformer Single Phase 230/400V 115/230V 400VA
Transformer control and signal mono terminals w/screw - 230 - 400/115 - 230V 400VA
Automation > One-phase control transformer
ACCESSORIES CONTROL AND CONTROL PANELS
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Legrand transformer 044266 is an inductive device utilized in industrial installations to safely step down main voltages or provide electrical separation between supply circuits and low-voltage control hardware.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Primary voltage 2 (EF006126): 230 V
- Built as isolating transformer (EF007238): Yes
- Height (EF000040): 140 mm
- Primary voltage 1 (EF006125): 215 V
- Degree of protection (IP) (EF005474): IP2X
- Primary voltage 4 (EF007410): 385 V
- Primary voltage 5 (EF007411): 400 V
- Built as safety transformer (EF007235): No
- Rated apparent power (EF008864): 400 VA
- Primary voltage 6 (EF007412): 415 V
- Primary voltage 3 (EF006127): 245 V
- Secondary voltage 1 (EF007472): 115 V
- Relative short circuit voltage (EF007452): 4.08 %
- Secondary voltage 2 (EF007474): 230 V
- Type of insulation material according to IEC 85 (EF007299): B
- Short-circuit-proof (EF007332): No
More info
▲
IP2x or xxB up to 400VA IP xxA above 400VA - IK 04 Conform to IEC/EN 61558-2-2 and 2-4 or 2-6 UL506 and CSA C22-2-No66 Products suitable for building into equipment conforming to EN 61131-2, EN 60204-1 and EN 60439-1 standards Insulated covers up to 1000VA provided Interference/disturbance filter included Screw fix to mounting plate or clip on to DIN rail up to 250VA Supplied with 0V/Earth connection link up to 1000VA
| Built as safety transformer | No |
|---|---|
| Built as isolating transformer | Yes |
| Built as energy saving transformer | No |
| Primary voltage 1 | 215-215 V |
| Primary voltage 2 | 230-230 V |
| Primary voltage 3 | 245-245 V |
| Primary voltage 4 | 385-385 V |
| Primary voltage 5 | 400-400 V |
| Primary voltage 6 | 415-415 V |
| Secondary voltage 1 | 115-115 V |
| Secondary voltage 2 | 230-230 V |
| Rated apparent power | 400 VA |
| Type of insulation material according to IEC 85 | B |
| Short-circuit-proof | No |
|---|---|
| Relative short circuit voltage | 4.08 % |
| Width | 120 mm |
| Height | 140 mm |
| Depth | 140 mm |
| Degree of protection (IP) | IP2X |
| Ring core | No |
| Suitable for mounting on PCB | No |
| Suitable for distribution board | No |
| degree of impact strength (IK) | IK04 |
| Voltage type | AC |
| Terminal marking indication | Yes |
| Connection type | Screwed terminal |