LEGRAND 044261 044261 LEGRAND TRANS.230-400/115-230V 40VA View larger
Images are for illustrative purposes only. Please refer to data sheet for details

044261 LEGRAND TRANS.230-400/115-230V 40VA

044261

044261

LEGRAND

1 Pcs.

TRANS.230-400/115-230V 40VA Legrand Safety Isolating Transformer Single Phase 230/400V 115/230V 40VA Transformer control and signal mono terminals w/screw - 230/400 - 115/230 40VA

Automation > One-phase control transformer
ACCESSORIES CONTROL AND CONTROL PANELS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Built by Legrand as part number 044261, this control transformer provides dependable voltage adaptation for industrial control panels and automation setups. It ensures proper electrical isolation and safe power delivery to low-voltage automation components.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Primary voltage 2 (EF006126): 230 V
  • Built as isolating transformer (EF007238): Yes
  • Height (EF000040): 78 mm
  • Primary voltage 1 (EF006125): 215 V
  • Degree of protection (IP) (EF005474): IP2X
  • Primary voltage 4 (EF007410): 385 V
  • Primary voltage 5 (EF007411): 400 V
  • Built as safety transformer (EF007235): No
  • Rated apparent power (EF008864): 40 VA
  • Primary voltage 6 (EF007412): 415 V
  • Primary voltage 3 (EF006127): 245 V
  • Secondary voltage 1 (EF007472): 115 V
  • Relative short circuit voltage (EF007452): 10.06 %
  • Secondary voltage 2 (EF007474): 230 V
  • Type of insulation material according to IEC 85 (EF007299): B
  • Short-circuit-proof (EF007332): No

More info

▲
IP2x or xxB up to 400VA IP xxA above 400VA - IK 04 Conform to IEC/EN 61558-2-2 and 2-4 or 2-6 UL506 and CSA C22-2-No66 Products suitable for building into equipment conforming to EN 61131-2, EN 60204-1 and EN 60439-1 standards Insulated covers up to 1000VA provided Interference/disturbance filter included Screw fix to mounting plate or clip on to DIN rail up to 250VA Supplied with 0V/Earth connection link up to 1000VA
Built as safety transformerNo
Built as isolating transformerYes
Built as energy saving transformerNo
Primary voltage 1215-215 V
Primary voltage 2230-230 V
Primary voltage 3245-245 V
Primary voltage 4385-385 V
Primary voltage 5400-400 V
Primary voltage 6415-415 V
Secondary voltage 1115-115 V
Secondary voltage 2230-230 V
Rated apparent power40 VA
Type of insulation material according to IEC 85B
Short-circuit-proofNo
Relative short circuit voltage10.06 %
Width94 mm
Height78 mm
Depth113 mm
Degree of protection (IP)IP2X
Ring coreNo
Suitable for mounting on PCBNo
Suitable for distribution boardYes
degree of impact strength (IK)IK04
Voltage typeAC
Terminal marking indicationYes
Connection typeScrewed terminal

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.