LAPP 7072400 7072400 SERVO LK INX-0209 4X2X0,25+2X1 LAPP SERVO LK INX-0209 4X2X0,25+2X1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

7072400 SERVO LK INX-0209 4X2X0,25+2X1 LAPP SERVO LK INX-0209 4X2X0,25+2X1

7072400

7072400

SERVO LK INX-0209 4X2X0,25+2X1

LAPP

1 Pcs.

SERVO LK INX-0209 4X2X0,25+2X1 SERVO cables in acc. to INDRAMAT® Standard INK

Cables > Data and communication cable
ÖLFLEX-SERVO cabling

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Servomotor- and feedback cables in acc. to INDRAMAT® standard, for dynamic power chain application, UL/CSA AWM certified

  • Servo drives
  • PUR outer sheath
  • EMC-compliant

Benefits

  • Allows much faster speed and accelerations which increases the economic efficiency of the machines
  • Multi-standard certification reduces part varieties and saves costs
  • Increased durability under harsh conditions thanks to robust PUR outer sheath
  • Resistant to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media

Application range

  • Connecting cable between servo controller and encoder/resolver
  • Connecting cable between servo controller and motor
  • Particularly in wet areas of machine tools and transfer lines
  • Assembly lines, production lines, in all kinds of machines

Product features

  • Designed for 5 million alternating bending cycles
  • For horizontal travel distances up to 100m
  • Abrasion and cut-resistant, halogen-free, oil-resistant
  • Flame-retardant according to IEC 60332-1-2 & CSA FT1

Norm references / Approvals

  • Power cable:
    UL Style 20234, CSA AWM I/II A/B
  • Signal cables:
    UL Style 20236, CSA AWM I/II A/B
  • UL File No. E63634
  • For use in power chains: Please comply with assembly guideline Appendix T3

Product Make-up

  • In accordance with INDRAMAT® standard INK (also suitable for pre-assembled versions, IKS and IKG)
  • Core insulation: TPE
  • Refer to data sheet for more details
  • Tinned-copper braiding
  • PUR outer sheath, orange (RAL 2003)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000104
  • ETIM 6.0 Class-Description: Control cable

Core identification code

  • Details see datasheet

Conductor stranding

  • Extra-fine wire according to IEC 60228 class 6

Minimum bending radius

  • Power cable:
    Fixed installation: 4 x outer diameter
    For flexible use: 7.5 x outer diameter
  • Signal cables:
    Fixed installation: 5 x outer diameter
    For flexible use: 10 x outer diameter

Nominal voltage

  • Power cable:
    - Power cores:
    U0/U 600/1000 V (IEC)
    1000 V (UL/CSA)
    - Control cores:
    250 V AC (IEC)
    1000 V (UL/CSA)
  • Signal cables:
    300 V (IEC), 300 V (UL/CSA)

Test voltage

  • Power cable:
    Power cores: 4000 V
    Control cores: 2000 V
  • Signal cables: 500 V

Protective conductor

  • G = with GN-YE protective conductor

Temperature range

  • Flexing: -30°C to +80°C
  • Fixed installation: -50°C to +80°C

Bending cycles & operation parameters

  • 5 mio. cycles

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.