View larger
7027090 ÖLFLEX TRUCK 470P 10x1,5+3x2,5+1x(2x1,5) LAPP ÖLFLEX TRUCK 470P 10x1,5+3x2,5+1x(2x1,5)
7027090
7027090
ÖLFLEX TRUCK 470P 10x1,5+3x2,5+1x(2x1,5)
LAPP
1 m.
Cables > Power cable less 1 kV, for moving application
Control cables for special applications
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a robust control cable, the 7027090 ÖLFLEX TRUCK 470P 10x1,5+3x2,5+1x(2x1,5) LAPP ÖLFLEX TRUCK 470P 10x1,5+3x2,5+1x(2x1,5) handles demanding mechanical stresses. Multi-conductor vehicle and commercial transport cabling is typically used in utility trucks, mobile machinery, and agricultural equipment to connect exterior electronic loads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Core insulation: Based on PVC
- Temperature range: Fixed installation: -40°C to +85°C
- ETIM 5.0 Class: EC000104 Control cable
- ETIM 6.0 Class: EC000104 Control cable
More info
▲ÖLFLEX® TRUCK 470 P FLRYY11Y - PUR/PVC power and control cable for commercial vehicles, truck applications, 60V DC, ADR, TÜV, ISO6722, ISO4141-3
- For commercial verhicles
- For hazardous materials transportation
- Hydrolysis and microbe resistant
Benefits
- Special ADR approval
- ADR approval enables use in vehicles transporting hazardous goods
Application range
- For commercial verhicles
- Wiring of electrical equipments in all trailers and semi-trailers
Product features
- UV-resistant
- Resistant to cold temperatures
- Resistant to most oils, chemicals and weather conditions
- Resistant to hydrolysis and microbes
Norm references / Approvals
- ISO 4141 and DIN/ISO 6722
Product Make-up
- Conductor made of bare copper wires
- Core insulation: Based on PVC
- Special PVC-based inner sheath
- Outer sheath made of special polyurethane
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- ISO 4141-3
Capacity of data pairs
- Related to length between cores, max. 50 pF/m and between each data transmission core and all other cores in the cable, max. 100 pF/m
Conductor stranding
- Fine wire according to DIN/ISO 6722
Minimum bending radius
- 12 x outer diameter
Nominal voltage
- 60 V
Test voltage
- 5 kV rms for at least 5 min.
Temperature range
- Fixed installation: -40°C to +85°C
- Area of application, Class A