For additional information regarding international plugs, please refer to our cable configurator at www.lappkabel.de
Apart from the cable related application restrictions to be paid attention to according to the application standard EN 50565-2 for this PVC cable H03VV-F, the fact that brighter outer sheath colours deviating from black significantly reduce the UV resistance of the outer sheath and, thus, the outdoor usability of the entire, finished cable has to be respected, too
Product Make-up
1st end: Gated, right-angled earthing-type plug with double earthing contact
Other end: 30 mm dismantled, with protection sleeves for the ends of the conductor
Alternatively, on request: 1st end with moulded right-angled earthing-type plug with twin earthed contact, 2nd end with moulded, straight IEC coupling (see image)
Classification ETIM 5
ETIM 5.0 Class-ID: EC001576
ETIM 5.0 Class-Description: Power cord
Classification ETIM 6
ETIM 6.0 Class-ID: EC001576
ETIM 6.0 Class-Description: Power cord
Core identification code
HD 308/VDE 0293-308: 3-core with protective conductor
Conductor stranding
Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
Nominal voltage
U0: 250 V AC
Test voltage
2000 V
Protective conductor
G = with GN-YE protective conductor
Temperature range
5°C to 60°C