LAPP 61713014 61713014 SILVYN HIPROJACKET NW 29 LAPP SILVYN HIPROJACKET NW 29 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

61713014 SILVYN HIPROJACKET NW 29 LAPP SILVYN HIPROJACKET NW 29

61713014

61713014

SILVYN HIPROJACKET NW 29

LAPP

15 m.

SILVYN HIPROJACKET NW 29 SILVYN® HIPROJACKET

Cables > Cable insulation hose
SILVYN cabling

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

SILVYN® HIPROJACKET is a fireproof cable protection conduit that protects the inner from flames and liquid metal with a temperature up to +1640 °C

  • Outstanding protection for extreme impact of heat
  • Hazard Level: HL 3

Benefits

  • Heat-resistant
  • Flexible
  • Temporarily reduces the temperature in the conduit by up to 30 %
  • The protection rating increases to IP67 if SILVYN® HIPROSILTAPE is also used

Application range

  • Heavy industry, iron and steel works, foundries, glass and ceramic processing, chemical industries
  • Steel industry
  • Railway applications / vehicle construction
  • Mechanical engineering
  • Used in areas where cables and wires are exposed to extreme heat

Product Make-up

  • Woven glass fibre conduit
  • Iron oxide silicone coat

Note

  • The manufacturing process of silicone may result in small air bubbles and openings in the outer sheath, which do not affect the product properties.

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC002254
  • ETIM 5.0 Class-Description: Cable insulation hose

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC002254
  • ETIM 6.0 Class-Description: Cable insulation hose

Certifications

  • EN 45545-2 HL1 / HL2 / HL3
    NF F 16-101 I2/F1
    NF EN ISO 11925-2
    DIN 5510-2 S4/SR2/ST2
    SAE AS 1072 Type 2

On request

  • 30m PU

Colour delivered

  • Red

Material

  • Glass fibre with iron oxide silicone coat LOI 39,2

Protection rating

  • IP 54 in combination with SILVYN® HIPROJACKET AMG fitting
  • IP 67 if SILVYN® HIPROSILTAPE is also used

Temperature range

  • -55°C to +260 °C permanent temp.
  • +800°C for approx. 20 min (flame treatment)
    +800°C for approx. 20 min (radiation heat)
    +1640°C for approx. 15-30 sec (liquid-metal contact)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.