View larger
4726036 H07Z-K 90°C 1X16 BN LAPP H07Z-K 90°C 1X16 BN
4726036
4726036
H07Z-K 90°C 1X16 BN
LAPP
100 m.
Cables > Power cable less 1 kV, for permanent installation
Single cores
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 4726036 H07Z-K 90°C 1X16 BN LAPP H07Z-K 90°C 1X16 BN serves as a single core cable utilized for internal electrical installations and building distribution networks. Electricians rely on these standard hookup wires to route power safely through conduits, switchboards, and junction boxes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- CPR: Article number choice under www.lappkabel.com/cpr
- Core insulation: Halogen-free
- OD ≤ 8 mm: 4 x OD*/2 x OD**
- 8 < OD ≤ 12 mm: 5 x OD*/3 x OD**
- OD > 12 mm: 6 x OD*/4 x OD**
- U0/U: 450/ 750 V
- During installation: -5°C bis +90°C Fixed installation: -40°C bis +90°C
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
More info
▲H07Z-K 90°C, <HAR>, halogen-free single core, harmonised, for wiring in control cabinets, nominal voltage 450/750V
- CPR: Article number choice under www.lappkabel.com/cpr
- Halogen-free and harmonised (HAR)
- For expanded ambient temperatures
and higher conductor cross-sections
see ÖLFLEX® HEAT 125 SC
Benefits
- Protection of human life and the environment thanks to the avoidance of the formation of acid in case of fire
- Time-saving assembly
Application range
- For wiring of lamps, devices, switchgear cabinets and distribution boxes
- For installation in tubes, on, in and under plaster as well as in closed installation ducts
- In building with a high density of people or valuable assets
- For use in dry rooms
- For expanded ambient temperatures
and higher conductor cross-sections
see ÖLFLEX® HEAT 125 SC
Product features
- The insulation material is halogen-free and free of other materials which could release toxic gases in the event of fire
- Low amount of corrosive gases in the event of fire
- Low smokes/low smoke density in the event of fire according to IEC 61034
- Flame-retardant according IEC 60332-1-2
Norm references / Approvals
- <HAR> cable type certification acc. EN 50525-3-41
- No cable type certified core insulation colours according to EN 50525-1/ VDE 0285-525-1: transparent, green (single colour), yellow (single colour), all double colours (except of green-yellow and yellow-green)
Product Make-up
- Fine-wire strand made of bare copper wires
- Core insulation: Halogen-free
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
Conductor stranding
- Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
Minimum bending radius
- According to EN 50565-1
- OD ≤ 8 mm: 4 x OD*/2 x OD**;
8 < OD ≤ 12 mm: 5 x OD*/3 x OD**;
OD > 12 mm: 6 x OD*/4 x OD**
Nominal voltage
- U0/U: 450/ 750 V
Test voltage
- 2500 V
Current rating
- VDE 0298-4
- EN 50565-1/ VDE 0298-565-1
Temperature range
- During installation: -5°C bis +90°C
Fixed installation: -40°C bis +90°C