4151201 SC 2.2 1X50 BK LAPP Multi-Standard SC 2.2 1X50 BK
4151201
4151201
SC 2.2 1X50 BK
LAPP
500 m.
Cables > Power cable less 1 kV, for permanent installation
Single cores
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Heavy-duty electrical installations benefit from the high-capacity power distribution provided by the Lapp 4151201 multi-standard single core cable. Heavy gauge single core conductors ensure efficient, secure energy transfer across industrial switchgear and machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Higher maximum conductor temperature - H07V2-K: +90 PC according to EN 50525-2-31
- CPR: Article number choice under www.lappkabel.com/cpr
- OD ≤ 8 mm: 4 x OD*/2 x OD**
- 8 < OD ≤ 12 mm: 5 x OD*/3 x OD**
- OD > 12 mm: 6 x OD*/4 x OD**
- HAR / IEC: U0/U: 450/750 V
- UL (AWM): U: 1000 V
- UL (MTW): U: 600 V
- CSA (TEW): U: 600 V
- Fixed installation: HAR/IEC: -40QC to +90QC
- UL (AWM): up to +105QC
- UL (MTW): up to +90QC
- CSA (TEW): up to +105QC
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
More info
▲Lapp Kabel® MULTI-STANDARD SC 2.2, power and control cable, PVC single core, field wiring, UL MTW VW-1, UL AWM 10269 1000 V, CSA TEW FT1, HAR H07V2-K +90°C
- Higher maximum conductor temperature - H07V2-K: +90 °C according to EN 50525-2-31
- Higher voltage range according to UL
- CPR: Article number choice under www.lappkabel.com/cpr
Benefits
- For use in the most important global markets
- Reduction in technical documentation
- Easier storage; increases the cost-effectiveness of the production process
- Works with "Conductor end sleeves XL, insulated"
Application range
- Factory wiring
- Field wiring
- Internal wiring of devices and in control cabinets
- Protected installation in and on lighting equipments
- Green insulated single cores ≥ 4 AWG are usable as EGC/ Equipment Grounding Conductor on cable tray according to NFPA 70 (NEC)
Product features
- Flame-retardant according IEC 60332-1-2
- Flame-retardant according to UL VW1/CSA FT1
- Oil-resistant
Norm references / Approvals
- Multi-standard cables have conductor strands with nominal sizes in mm² or AWG/kcmil. The master size is mentioned in the table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related secondary size the cross-section of the conductor mostly works out to be greater than the
specified nominal value. - Cable type certifications: <HAR> H07V2-K acc. EN 50525-2-31, UL AWM
style 10269 (by UL acc. UL standard UL 758, U.I. Lapp GmbH's UL AWM file number: E63634), (UL) MTW (by UL acc. UL standard UL 1063, U.I. Lapp GmbH's (UL) MTW
file number: E198296), CSA TEW (by CSA acc.
CSA standard CSA C22.2 No. 127, CSA class 5835-01)
Product Make-up
- Fine-wire strand made of tinned-copper wires
- Special PVC-based core insulation
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
Conductor stranding
- Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
Minimum bending radius
- OD ≤ 8 mm: 4 x OD*/2 x OD**;
8 < OD ≤ 12 mm: 5 x OD*/3 x OD**;
OD > 12 mm: 6 x OD*/4 x OD**
Nominal voltage
- HAR / IEC: U0/U: 450/750 V;
UL (AWM): U: 1000 V; - UL (MTW): U: 600 V;
CSA (TEW): U: 600 V
Temperature range
- Fixed installation:
HAR/IEC: -40°C to +90°C;
UL (AWM): up to +105°C; - UL (MTW): up to +90°C;
CSA (TEW): up to +105°C