View larger
302406STP UNITRONIC 300 STP 24/6PR LAPP UNITRONIC 300 STP 24/6PR
302406STP
302406STP
UNITRONIC 300 STP 24/6PR
LAPP
1 m.
Cables > Data and communication cable
flexible data cable transfer from special cable
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a robust multi-pair data cable, the Lapp 302406STP UNITRONIC 300 STP 24/6PR supports industrial electronic equipment and instrumentation installations. Shielded twisted-pair construction safeguards low-voltage communication lines against external noise sources in harsh plant floor environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1
- Outer jacket: Specially Formulated PVC, dark gray (similar to RAL 7005)
- Exception single-paired, 24-22 AWG: black, white
- Occasional flexing: 15 x outer diameter
- Fixed installation: 6 x outer diameter
- according to UL: 300 V
- IEC: not for power transmission
- Occasional flexing/ North America temperature: -25°C to +105°C (AWM for USA: +80°C)
- Fixed installation/ North America temperature: -40°C to +105°C (AWM for USA: +80°C)
More info
▲UNITRONIC® 300 STP: Low-frequency PVC data cable, UL/CSA AWM, CMG, Further Tray Cable listings for unprotected use on Tray, Screened, Twisted Pairs, -25°C/105°C
- Other sizes on request
- Especially for 20 AWG and 18 AWG: With standard core color code, up to 37 pairs producible/ With non-standard color code, e.g., with green-yellow grounding conductor, up to 50 pairs
Benefits
- Wide application range due to multiple certifications
- Cost-saving, easy installation due to omission of closed raceways (suitable for open wiring)
- Overall braid minimises electrical
interference - Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
Application range
- Control and signal cables for internal and external wiring
- For the North American market
- On the basis of CMG, PLTC or ITC direct laying on cable tray in the USA, in conjunction with -ER (Exposed Run) for unprotected transition sections with a length of not more than 6 ft. each
- Thanks to the DIRECT BURIAL approval, direct burial of versions with the nominal conductor cross-section 18 AWG in the USA
- Torsion resistant up to ±150 °/m for the drip loop of wind turbine generators
Product features
- Oil-resistant according to UL OIL RES I
Norm references / Approvals
- USA: (UL) CMG [E130334], (UL) PLTC-ER (18 AWG) [E216027], (UL) PLTC (>24 AWG) [E216027], (UL) ITC-ER (18 AWG) [E196134], UL AWM Style 2464 [E100338], DIR BUR (18 AWG)
- CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1
Product Make-up
- Fine-wire strand made of tinned-copper wires
- Core insulation made of PVC
- TP structure
- Overall foil tape wrapping, drain wire,
tin-plated copper braiding (75 % coverage) - Outer jacket: Specially Formulated PVC, dark gray (similar to RAL 7005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Core identification code
- Pair 1: black, red
Pair 2: black, white
Pair 3: black, green
Pair 4: black, blue
Pair 5: black, yellow
Pair 6: black, brown - Exception single-paired, 24-22 AWG: black, white
Torsion movement in WTG
- TW-0 & TW-2, refer to Appendix T0
Minimum bending radius
- Occasional flexing: 15 x outer diameter
- Fixed installation: 6 x outer diameter
Nominal voltage
- according to UL: 300 V
IEC: not for power transmission
Test voltage
- 1500 V
Temperature range
- Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)
- Fixed installation/ North America: -40°C to +105°C (AWM for USA: +80°C)