LAPP 302002STP 302002STP UNITRONIC 300 STP 20/2PR LAPP UNITRONIC 300 STP 20/2PR View larger
Images are for illustrative purposes only. Please refer to data sheet for details

302002STP UNITRONIC 300 STP 20/2PR LAPP UNITRONIC 300 STP 20/2PR

302002STP

302002STP

UNITRONIC 300 STP 20/2PR

LAPP

1 m.

UNITRONIC 300 STP 20/2PR UNITRONIC® 300 STP

Cables > Data and communication cable
flexible data cable transfer from special cable

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Lapp 302002STP UNITRONIC 300 STP 20/2PR multi-pair data cable delivers protected signal connections for industrial control panels and instrumentation circuits. Shielded pairing safeguards transmission accuracy in electrically noisy surroundings. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1
  • Outer jacket: Specially Formulated PVC, dark gray (similar to RAL 7005)
  • Exception single-paired, 24-22 AWG: black, white
  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 6 x outer diameter
  • according to UL: 300 V IEC: not for power transmission
  • Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)
  • Fixed installation/ North America: -40°C to +105°C (AWM for USA: +80°C)
  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable
  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

More info

▲

UNITRONIC® 300 STP: Low-frequency PVC data cable, UL/CSA AWM, CMG, Further Tray Cable listings for unprotected use on Tray, Screened, Twisted Pairs, -25°C/105°C

  • Other sizes on request
  • Especially for 20 AWG and 18 AWG: With standard core color code, up to 37 pairs producible/ With non-standard color code, e.g., with green-yellow grounding conductor, up to 50 pairs

Benefits

  • Wide application range due to multiple certifications
  • Cost-saving, easy installation due to omission of closed raceways (suitable for open wiring)
  • Overall braid minimises electrical
    interference
  • Decoupling of circuits by means of
    twisted-pair (TP) design (crosstalk effects)

Application range

  • Control and signal cables for internal and external wiring
  • For the North American market
  • On the basis of CMG, PLTC or ITC direct laying on cable tray in the USA, in conjunction with -ER (Exposed Run) for unprotected transition sections with a length of not more than 6 ft. each
  • Thanks to the DIRECT BURIAL approval, direct burial of versions with the nominal conductor cross-section 18 AWG in the USA
  • Torsion resistant up to ±150 °/m for the drip loop of wind turbine generators

Product features

  • Oil-resistant according to UL OIL RES I

Norm references / Approvals

  • USA: (UL) CMG [E130334], (UL) PLTC-ER (18 AWG) [E216027], (UL) PLTC (>24 AWG) [E216027], (UL) ITC-ER (18 AWG) [E196134], UL AWM Style 2464 [E100338], DIR BUR (18 AWG)
  • CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1

Product Make-up

  • Fine-wire strand made of tinned-copper wires
  • Core insulation made of PVC
  • TP structure
  • Overall foil tape wrapping, drain wire,
    tin-plated copper braiding (75 % coverage)
  • Outer jacket: Specially Formulated PVC, dark gray (similar to RAL 7005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

Core identification code

  • Pair 1: black, red
    Pair 2: black, white
    Pair 3: black, green
    Pair 4: black, blue
    Pair 5: black, yellow
    Pair 6: black, brown
  • Exception single-paired, 24-22 AWG: black, white

Torsion movement in WTG

  • TW-0 & TW-2, refer to Appendix T0

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 6 x outer diameter

Nominal voltage

  • according to UL: 300 V
    IEC: not for power transmission

Test voltage

  • 1500 V

Temperature range

  • Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)
  • Fixed installation/ North America: -40°C to +105°C (AWM for USA: +80°C)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.