View larger
301606S UNITRONIC 300 S 16/6C LAPP UNITRONIC 300 S 16/6C
301606S
301606S
UNITRONIC 300 S 16/6C
LAPP
1 m.
Cables > Data and communication cable
flexible data cable transfer from special cable
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Lapp 301606S UNITRONIC 300 S 16/6C provides robust North American compliant data and control functionality tailored for industrial machinery wiring. Shielded multi-conductor cables are utilized extensively in automated control systems to ensure reliable data transfer and compliance with regional electrical standards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Designation of shielded version: Formerly "UNITRONIC® 300 CY", now "UNITRONIC® 300 S"
- CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1
- UNITRONIC® 300 S: with overall foil tape wrapping, drain wire, tin-plated copper braiding (75 % coverage)
- Outer jacket: Specially Formulated PVC
- Color of the outer jacket: Dark gray (similar to RAL 7005)
- During installation: 4 x cable diameter
- Screened: 6 x outer diameter
- according to UL: 300 V IEC: not for power transmission
- Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)
- Fixed installation/ North America: -40°C to +105°C (AWM for USA: +80°C)
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
More info
▲UNITRONIC® 300/300 S: unscreened or screened Low-frequency PVC data cable, UL/CSA AWM, CMG, Further Tray Cable listings for Cable tray installation, -25°C/105°C
- Designation of shielded version:
Formerly "UNITRONIC® 300 CY",
now "UNITRONIC® 300 S" - Other sizes on request
- Especially for 20 AWG and 18 AWG: With standard core color code, up to 60 conductors producible/ With non-standard color code, e.g., green-yellow grounding conductor, up to 100 cores
Benefits
- Wide application range due to multiple certifications
- Cost-saving, easy installation due to omission of closed raceways (suitable for open wiring)
Application range
- Control and signal cables for internal and external wiring
- For the North American market
- On the basis of CMG, PLTC or ITC direct laying on cable tray in the USA, in conjunction with -ER (Exposed Run) for unprotected transition sections with a length of not more than 6 ft. each
- Thanks to the DIRECT BURIAL approval, direct burial of versions with the nominal conductor cross sections 18 AWG and 16 AWG is normatively permitted in the USA
- Torsion resistant up to ±150 °/m for the drip loop of wind turbine generators
Product features
- Oil-resistant according to UL OIL RES I
- Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
Norm references / Approvals
- USA: (UL) CMG [E130334], (UL) PLTC-ER (18 AWG + 16 AWG) [E216027], (UL) PLTC (>24 AWG) [E216027], (UL) ITC-ER (18 AWG + 16 AWG) [E196134], UL AWM Style 2464 [E100338], DIR BUR (18 AWG + 16 AWG)
- CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1
Product Make-up
- Fine-wire strand made of tinned-copper wires
- Core insulation made of PVC compound
- UNITRONIC® 300 S: with overall foil tape wrapping, drain wire,
tin-plated copper braiding (75 % coverage) - Outer jacket: Specially Formulated PVC
- Color of the outer jacket: Dark gray (similar to RAL 7005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Core identification code
- refer to Appendix T9
Conductor stranding
- Fine wire
Torsion movement in WTG
- TW-0 & TW-2, refer to Appendix T0
Minimum bending radius
- During installation: 4 x cable diameter
- Screened: 6 x outer diameter
Nominal voltage
- according to UL: 300 V
IEC: not for power transmission
Test voltage
- 1500 V
Temperature range
- Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)