▲HITRONIC® HRH Breakout cable, separable, for direct connector mounting, J-V(ZN)HH, available with multimode fibers type OM1, OM2, OM3 and OM4 or single mode OS2
- CPR: Registration number and classification in www.lappkabel.com/cpr
- Breakout cable for direct mounting of connectors
proceeds
- Suitable for field mounting
- Universal cable for building wiring
- Very easy to install due to its compact design, high flexibility and small bending radius
- No electromagnetic interference because it does not contain metal parts (fully dielectric)
Scope of use
- For indoor use
- Tertiary wiring
- Local cabling - backbone network
- Type of laying: laying in pipes, gutters, trays, vertical conductors for buildings, empty polyamide pipes, plenums and technical floors
Product features
- Installation cable up to 12 fiber cores
- Non-flame-propagating and halogen-free outer shell
- Mechanically robust
Product composition
- 2.1 mm sub-reinforced cable with LSZH cover (identified by numbers)
- GRP core element for reinforcement
- Aramid filaments to improve behavior against mechanical stress
- LSZH interior and exterior covers
- Color: violet for OM4, aqua (RAL 6027) for OM3, orange (RAL 2003) for OM2 and OM1,
yellow for single-mode
ETS Classification 5
- ETIM 5.0 Class-ID: EC000034
- ETIM Class 5.0 Description: Fiber Optic Cable
ETTIM Rating 6
- ETIM 6.0 Class-ID: EC000034
- ETIM 6.0 Class-Description: Fiber Optic Conductor
Dimensions
- Fitted fibre (coated secondary fibre): 900 μm
- Subcable: 2.1 mm
Driver Identification Code
- Sucable: with black numbers
Type of fiber
- GOF - Glass Optical Fibre
Standard name
- J-V(ZN)HH
optical values
- See the data sheet
Type of optical fiber
- Conductor material: glass
- Coating material: glass
Minimum radius of curvature
- Fixed: ≥ 15 x outer diameter
- Occasional bending: ≥ 20 x outer diameter
Temperature range
- Fixed installation: -20°C to +70°C